Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T06CM04128
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/17/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 07/18/2006 | JOE LINVILLE | NPPO | REVIEW | Approved | Exception. |
| 07/18/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Submit a revised landscape plan. Include all data from previous plans. 2) Show all existing landscape plantings and as well as new improvements on the plans. DS 2-07.2.0 3) The refuse storage area may not be located in the landscape buffer. 4) Revise the plans to provide the minimum required buffer width (5') at all points. |
| 08/11/2006 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 08/31/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: MEXICO LINDO T06CM04128 Site Plan (1st Review) TRANSMITTAL DATE: August 31, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. The following comments are based on a 24% building area expansion resulting in a full code compliance review of the expansion area only. 1. The existing use is listed as General Merchandise Sales "28", Provide the proposed use of "Food and Beverage Sales "28" Land Use Code Sec2.5.3.2.B (D.S. 2-02.2.1.A.31) 2. Per the MS&R, Valencia is designated as having a total right-of-way of 150 feet (75' ½ right-of-way). The site plan shows a right-of-way of 60'-4" well short of the 75' half required. Label and dimension correct right-of-way dimensions for both Valencia and Missiondale. (D.S. 2-02.2.1.A.19) 3. Label the zoning classification for the property located to the north. (D.S. 2-02.2.1.A.28) 4. Provide lot bearings & curve data. (radius at corner). (D.S. 2-02.2.1.A.5) 5. Per the attached Tenant Improvements with site improvements dated 04/06/01, a "10'x10' Trash Dumpster per Development Standards 6-01.0" is shown in the northeast corner of the south parking area. It appears that the new location is shown just east of the existing loading zone, for the new location demonstrate maneuvering area for both the dumpster and loading zone. (D.S. 2-02.2.1.14 & 32) If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180. C:\planning\site\t06cm04128.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 09/08/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/11/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 09/11/2006 | SUE REEVES | REJECT SHELF | Completed |