| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/14/2006 | MARTIN BROWN | FIRE | REVIEW | Denied | Structure appears to be open and closer than 10' to property line. Clarify structure satisfies seperation requirements of 2003 IBC. |
| 07/20/2006 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 07/20/2006 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | The loading zone is being relocated a distance of approximately 20 feet to the northwest of where it was shown on the approved plan in order to allow room for the proposed storage canopy. A six (6) foot high screen wall is required to screen the loading area from adjacent I-10 right-of-way. Submit a revised landscape plan detailing required screening for the loading zone. LUC Table 3.7.2-I |
| 08/11/2006 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: August 11, 2006 SUBJECT: Exterior Storage Canopy- Site Plan Review TO: Jerry Dusenberry LOCATION: 3143 N Freeway Industrial Loop, T13S R13E Sec34, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: T06CM04110 SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted site plan. Engineering Division recommends approval of the site at this time. For any questions call me at 791-5550, extension 1189. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 08/31/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: BORDER PRODUCTS - 3143 N. Freeway Industrial Loop T06CM04110 Site Plan (1st Review) TRANSMITTAL DATE: September 5, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. The following comments are based on a 24% building area expansion resulting in a full code compliance review of the expansion area only. 1. The last approved site plan that was submitted for this review only shows lots 12 & 13, the proposed site plan shows lots 12, 13 & 14, if lot 14 is being added for this review then this would be more than a 25% increase in lot size requiring full code compliance. If there is another approved site plan showing the three lots provide it on the next submittal. 2. Per the Pima County Assessor's Record Map it appears that lots 12, 13 & 14 have been combined into one lot. This being the case remove the interior lot lines from the site plan. 3. Add "CONSTRUCTION/HEAVY EQUIPMENT WHOLESALING "34" under Current Use - Wholesale - Group 34. D.S. 2-02.2.1.31 4. Zoning would be willing to provide an over the counter review if a City approved site plan showing all three parcels can be provided along with the corrections for the additional comments. Call Steve Shields to schedule an appointment. If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180. C:\planning\site\t06cm04110.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 09/05/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/06/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |