Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T06CM04005
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/13/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Denied | Floodplain Use Permit not yet approved. See T06OT02523. |
| 11/19/2006 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | November 17, 2006 CITY OF TUCSON - FIRST CHECK Tucson Appl. No. T060CM4005 Bureau Veritas Job No. 01006-1610066 Mr. James Li 2923 S. Foster Drive Tucson, Arizona 85730 Re: Plan Review: Li Guesthouse Address: 6417 E. Baylor Dear Mr. Li: Bureau Veritas North America has completed a review of the following documents on behalf of the City of Tucson: Plans: Two (2) copies of plans (4 sheets, 1 through 4) no dates, no stamps. Structural Calculations: None submitted with this review. Soils Letter/Report: None submitted with this review. Energy Compliance: None submitted with this review. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, BUREAU VERITAS Shelley Knuffke ICC Plans Examiner SK:pc F:\Tucson\01006-1610066pc1.doc enclosures A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). GENERAL REQUIREMENTS: No permit card included. FLOOR PLAN: Designate the locations of water heaters. Indicate the location of the T and P relief line from the water heater to the exterior of the building. Note the T and P relief line to be full size steel pipe or hard drawn copper tubing extending to the exterior of the building and terminating in a downward position not more than 2 feet or less than 6 inches above grade. The T and P relief line shall not terminate over walkways, patios, carports or other similar areas. IRC Section P2803.6.1. Provide the following note: A separate insulation inspection prior to drywall or an insulation certificate will be required at time of final. IRC Section N1101.3.1. Appliances having an ignition source shall be elevated such that the source of ignition is not less than 18 inches above the floor in garages. For the purpose of this section, rooms or spaces that are not part of the living space of a dwelling unit and that communicate with a private garage through openings shall be considered to be part of the garage. IRC Section M1307.3 FOUNDATION PLAN: All slabs and pads, including landings at all doors, shall be shown and their thickness specified. Indicate the slopes for exterior slabs. Specify thickness of landing outside door. Provide note: All plates (interior and exterior, load bearing and non-load bearing) shall be pressure treated or foundation grade redwood. IRC Section R403.1.3. All slabs and pads, including landings at all doors, shall be shown and their thickness specified. Indicate the slopes for exterior slabs. FRAMING PLAN: Note on the plan all lumber shall bear an approved grading stamp. MECHANICAL COMMENTS: Indicate access clearances and working space around HVAC equipment. IRC Section M1305. Show condensate line and secondary condensate line. IRC Section M1411.3 and M1411.3.1. PLUMBING COMMENTS: If gas is not used – delete all references to gas equipment and gas lines. Specify materials for waste, water and gas pipes. ELECTRICAL COMMENTS: Where ceiling fans are shown on the plans, provide an note indicating that only approved outlet boxes shall be used. NEC Article 370-27 ©, IRC Section E3904.4, E3805.8 and E4001.6. Please provide bonding to the interior water piping and above ground portion of gas piping systems. IRC Section E3509.6. Provide a note indicating all branch circuits that supply 125-volt, single-phase, 15 and 20-ampere receptacle outlets installed in dwelling unit bedrooms shall be protected by an arc-fault circuit interrupter(s). NEC Article 210-12(b). Provide at least one weatherproof receptacle outlet, not more than 6 feet 6 inches above grade and GFCI protected, at the front and back of each dwelling. IRC Section E3801.1 & E3802.3. Please provide a convenience receptacle outlet for the servicing of appliances (HVAC) within 25 feet of the appliance. IRC Section 3801. Surface mounted incandescent light fixtures in clothes closets shall maintain 12 inches between the fixture and the nearest point of storage. IRC Section E3903.11. If you have any questions regarding the above comments, please contact Shelley Knuffke at (520) 576-8400 between 8:00 A.M. to 5:00 P.M., M-F. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/21/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 11/21/2006 | SUE REEVES | REJECT SHELF | Completed |