Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM04002
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2006 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | August 28, 2006 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T06-CM04002 Bureau Veritas Job No. 01006-161029 Gary Pennington 6400 W Sunset Rd Tucson, Arizona 85743 Re: Plan Review: Poisl & Dugan SFR Address: TBD Bureau Veritas Company, has completed a review of the following documents on behalf of the City of Tucson: 1. Plans: Two (2) sets of plans (15 sheets, 1 through 15) 2. Truss Calculations: None provided. Structural Calculations: None provided. Energy Compliance: None provided. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas Randy McCoy, Senior Plans Examiner ICC Plans Examiner RM:tm c:/tucson\01006-161029pc1 enclosures Re: Stories: One Fire Sprinklers: No Building Area (sq. ft.): 2,565 (livable) 785 (covered porch) (garage) 541 (Storage) A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). MECHANICAL/PLUMBING: Condensate line for roof mount unit is not allowed to drain into VTR on roof per IPC901.4. ELECTRICAL: Smoke alarm missing on floor plan for hallway outside of slopping areas. Show smoke alarm circuit on Panel Schedule. Show proper circuit number for smoke alarms on electrical plan IRC 317.2. STRUCTURAL: Specify floor and roof live loads and dead loads R301 Note on plan. If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/30/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 08/30/2006 | SUE REEVES | REJECT SHELF | Completed |