Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM04002
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/17/2006 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | August 14th, 2006 CITY OF TUCSON - FIRST CHECK City of Tucson Permit #. No. T06CM04002 Bureau Veritas Job No. 01006-161-029 City of Tucson 201 N. Stone Ave. 1st Floor Tucson, AZ 85701 Re: Plan Review: Poisl/Dugan SFR Bureau Veritas has completed a review of the following documents on behalf of the Pima County: 1. Plans: Two (2) sets of plans (15 sheets, 1 through 15) 2. Truss Calculations: None provided. 3. Structural Calculations: None Provided These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and City of Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Our comments follow on the attached list. Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, BUREAU VERITAS Shelley K. Knuffke ICC Plans Examiner cc:skk enclosures Re: Stories: One Fire Sprinklers: No Building Area (sq. ft.): 2,565 (livable) 623 (garage) 785 (covered porches) 541 (storage) A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., Engineering, Public Works, Health, etc.). ARCHITECTURAL COMMENTS: Provide the following note: A separate insulation inspection prior to drywall or an insulation certificate will be required at time of final. IRC Section N1101.3.1. Glass in hazardous areas shall be safety glass. Specify on applicable floor plans and elevations. IRC Section 308. 3. Provide ICBO Evaluation Report number of all concrete or clay-type roofing. ELEVATIONS: 1. For Thin coat stucco systems over foam board note and specify the ICBO Evaluation Report number. STRUCTURAL COMMENTS: 1. City of Tucson has adopted the 2003 IRC. Please use current code. 2. Note and specify termite protection. IRC Section R324. 3. Note on the plan that all lumber shall bear an approved grading stamp. 4. Specify design criteria: floor and roof live loads and dead loads. IRC Section R301. MECHANICAL: 1. Show condensate line and secondary condensate line. IRC Section M141.3 and M1411.3.1. PLUMBING: 1. Provide drainage pipe isometric showing all drain, waste and vent piping. 2. Note that drainage piping serving fixtures which have flood level rims located below the elevation of the next upstream manhole cover of the public sewer shall be protected from backflow of sewage by a backwater valve. IRC Section P3008. ELECTRICAL: 1. Smoke Alarms shall receive their primary power from the building wiring with battery backup. Wiring shall be permanent without a disconnecting switch other than those required for overcurrent protection. Smoke alarm required in hallway, outside sleeping rooms. IRC Section 317.2 2. Provide access to hydro tub electric and motor/pump. 3. Note and specify that two or more 20 amp small appliance circuits shall be provided to serve the kitchen, breakfast room and dining room. Such circuits shall serve no other outlets. IRC Section E3603.2 and E3801.3.1. 4. Provide exterior light and switch at entry door to storage room. END OF REVIEW COMMENTS If you have any questions regarding the above comments, please contact Shelley Knuffke @ (520) 576-8400 8:00 A.M. to 5:00 P.M., M-F. |
| 08/21/2006 | JASON GREEN | ENGINEERING | REVIEW | Approved | Re-stamp of plans after 3rd party review. Re-stamp was done by Suzanne Bohnet on 7/17/2006. JG 08AUG06 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/21/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 08/21/2006 | SUE REEVES | REJECT SHELF | Completed |