Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM03878
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/09/2007 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | Febuary 07, 2007 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T06CM03878 Bureau Veritas Job No. 01006-161082 Ms. Barb McNaughton 2750 N. Pantano Road Tucson, Arizona 857151 Re: Plan Review: McNaughton Detached Barn Address: 2570 N. Pantano Rd Dear Ms. McNaughton: Bureau Veritas North America has completed a review of the following documents on behalf of the City of Tucson: Plans: Two (2) copies of plans (1 sheet) no dates, no stamps. Structural Calculations: Two (2) copies of structural calculations and trusses, no dates no wet seals. Soils Letter/Report: None submitted with this review. Energy Compliance: None submitted with this review. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, BUREAU VERITAS NORTH AMERICA Shelley Knuffke ICC Plans Examiner SK:pc F:\Tucson\01006-1610082pc1.doc enclosures McNaughton Detached Barn City of Tucson - First Check 2750 N. Bantano Rd Bureau Veritas Job No.:01006-161082 November 21, 2006 Page A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). GENERAL COMMENTS: Engineer’s wet seal must be provided on all structural calculations. Provide electrical plan: including wire sizing, panel schedule, trench depth, etc. If you have any questions regarding the above comments, please contact Shelley Knuffke at (520) 576-8400 between 8:00 A.M. to 5:00 P.M., M-F. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/13/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 02/13/2007 | SUE REEVES | REJECT SHELF | Completed |