Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T06CM03444
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit a separate landscape plan per DS 2-07.0. to verify that entire site meets current minimum requirements. Include with re-submittal any previously approved plans. 2. A street landscape border, per LUC 3.7.2.4, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. Portion of the site borders Saguaro St. landscaping is required. 3. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I 4. A 6' screen is required for outdoor storage adjacent to commercial properties per LUC Table 3.7.2-I. 5. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Additional tree is required for vehicle use area. 6. An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree within vehicle use area per LUC 3.7.2.3.A.1.c. Revise planters as necessary 7. Landscaping along parking lots where plants are susceptible to injury by vehicular traffic must be protected by appropriate means, such as curbs, bollards, or low walls per LUC 3.7.2.3.B. Include protection for canopy trees within vehicle use area. 8. All disturbed and unpaved areas including adjacent shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment for unpaved area. 9. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. 10. Additional comments may apply |
| 06/13/2006 | ANDREW CONNOR | NPPO | REVIEW | Approved | Exception |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/20/2006 | ADRIANNE OLIVO | OUT TO CUSTOMER | Completed |
| 06/20/2006 | SUE REEVES | REJECT SHELF | Completed |