Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T06CM03375
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2006 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 07/10/2006 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: July 10, 2006 SUBJECT: Single-Family Residence- Engineering Review ADDRESS: 5812 S Stewart Ave, Tucson Arizona 85706 PROPERTY OWNER: Robert Deeming LOCATION: T15S R14E Sec07 A portion of Parcel 140-25-2040, Bloodworth/Stewart Lot 4 REVIEWER: Jason Green, CFM ACTIVITY NUMBER: T06CM03375 SUMMARY: Engineering Division of Development Services Department has received and reviewed the Site Plan (T06CM03375) and Floodplain Use Permit (T06OT01571) for the above referenced property and recommends approval of the Site Plan and Floodplain Use Permit at this time. CONDITIONS OF PERMIT: 1) The associated improvements are with permit activity number T06OT01571 (Floodplain Use Permit) and T06CM03375 (site plans). 2) The applicant is authorized to use a portion of the City of Tucson flood-prone and/or erosion hazard area as shown on the subdivision plat covering this parcel as recorded in Book 56, Page 005, at the office of the Pima County Recorder, for the purpose of constructing a single family residence and driveway (located across a platted floodprone area). 3) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 4) This Floodplain Use Permit is issued prior to the approval of the improvement plans/permit. Copies of these documents will need to be kept in a readily accessible location on site at all times. 5) For purposes of this permit the following flood elevations shall be used: Base Flood Elevation (BFE) = 2541.4 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2542.4 feet NAVD 1988 Residence is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 6) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the single-family residence as well as the identity and location of all other equipment/machinery servicing the single-family residence. 7) Single-family residence is to remain completely outside of the platted 100-year floodplain as depicted on the approved site plan. 8) No future development is allowed within the platted 100-year floodplain without first obtaining a separate Floodplain Use Permit 9) Driveway is to be constructed at grade only. No culvert crossings without review/approval COT Engineering Division. Drive must provide positive drainage away from structure. If you have any questions, I can be reached at 791-5550, extension 1189. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 07/11/2006 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/11/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |