Permit Number: T06CM03269
Parcel: 10709058C

Address:
432 W GRANT RD

Review Status: Completed

Review Details: POST 3RD PARTY REVIEW

Permit Number - T06CM03269
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/06/2007 MARTIN BROWN FIRE REVIEW Approved
04/09/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied Approved site plan is required prior to building plan approval.
04/10/2007 GERRY KOZIOL WWM REVIEW Denied 1: CAPIN GRANT ROAD BRAKE SHOP - BRAKE PROS
2: APPROVED FOR 4" PRIVATE BUILDING SEWER CONNECTION TO 6" PUBLIC SEWER (NEED TO SHOW LOCATION/METHOD OF CONNECTION TO PUBLIC SEWER WITH THIS SUBMITTAL)
3: NEEDS WASTEWATER IWC TOM TOMCHAK REVIEW 579-5771 - 5025 W INA ROAD
04/16/2007 ROBERT SHERRY WATER REVIEW Denied 1. Provide a site plan showing the location of the water meter and the backflow assembly.

2. Provide a letter from Tucson Water confirming that the use of a 1" water meter will be allowed for this project (99.5 fixture units equates to a demand of 44 GPM).
04/19/2007 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
04/20/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Capin Grant Road Brake Shop
T06CM03269
Building Plan (1st Review)

TRANSMITTAL DATE: April 20, 2007

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please call Steve Shields,
(520) 837-4956

C:\planning\grading\t06cm01769.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
05/18/2007 DELMA ROBEY OUT TO CUSTOMER Completed