Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM03193
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/18/2006 | DROBEY1 | ZONING | REVIEW | Needs Review | |
| 09/18/2006 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | September 12, 2006 The City of Tucson Development Services 201 North Stone Avenue Tucson, AZ 85701 RE: GRAVINO RESIDENCE – 2nd REVIEW CITY OF TUCSON LOG NO. T06CM03193 WILLDAN PROJECT NO. 13881-6024 The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Antonio Moya. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms SFR Garage Patio N/A V-B 2048 528 184 No Smoke GENERAL COMMENTS: All Sheets NEW COMMENT: All lettering must be 1/8 “ high capitalized. Reference the City of Tucson Submittal Requirements. ARCHITECTURAL COMMENTS: Sheet 4 Provide access to each separate attic and under floor space that exceeds 30SF. Designate locations on the drawings. Openings shall not be less than 22” X 30” for attics or 18” X 24” for under floor space. Attic access shall provide a minimum of 30” of headroom and shall be located in a hallway or readily accessible space. Reference IRC Sections R807.1 and R408.3. COMMENT REMAINS: Not addressed. Sheet 6 For thin-coat stucco systems over foam board, note and specify the listing agency’s evaluation report number, system name and manufacturer, and note and specify the vapor barrier. Reference the City of Tucson Submittal Requirements. COMMENT REMAINS: Please provide evaluation report number. Sheet 7 The right elevation is inverted to how the floor plan is drawn. Please clarify. Reference IRC Section 106.1.1. COMMENT REMAINS: The bathroom window does not match with the window on the floor plan. Please clarify. Reference IRC Section 106.1.1. STRUCTURAL COMMENTS: Sheet 2 Please clarify spec note of 1500 pounds per square inch of assumed soil bearing value. Reference IRC Section 106.1.1. COMMENT REMAINS: Not addressed. Sheet 3 Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used. A soils report is not required unless any portion of the structure is to be supported on fill. Please clarify the spec on note #5 of 2000 pounds per square inch. Reference IRC Section R401.4. COMMENT REMAINS: Not addressed. Sheet 4 Specify lumber grade and species. Reference IRC Section R106.1.1. COMMENT REMAINS: Not addressed. PLUMBING COMMENTS: Sheet 12 Waterline: Provide the total fixture unit demand (based on Tables 6-4 & 7-3 or Tables L-1 & L-2). Reference UPC Section 610. COMMENT REMAINS: Not addressed. The City of Tucson has adopted the 2003 Uniform Plumbing Code with local amendments. All plans must reference the 2003 UPC with local amendments in its entirety. COMMENT REMAINS: Not addressed. MECHANICAL COMMENTS: Sheet 11 Show exhaust fan locations and exhaust duct terminations for bathrooms, water closet compartments and similar rooms in lieu of operable windows. Reference IRC Section R303.3. COMMENT REMAINS: Not addressed. If the heating or air conditioning equipment is located in the attic, show location of access, catwalk, and working platform. Show provisions for and route of secondary condensate drain. Reference IRC Sections M1305.1.3 and M1411.3. COMMENT REMAINS: Not addressed. ELECTRICAL COMMENTS: Sheet 9 Indicate the location of all disconnecting means for air conditioning and heating units, air handlers, compressors, and disconnects. Reference IRC Section E4001.5 and IRC Table E4001.5. COMMENT REMAINS: Not addressed. Indicate the location of convenience outlet(s), light switch(es), and a disconnect for attic heating and air conditioning equipment. Service outlet must be within 25’ of the equipment. Reference IRC Sections M1305.1.3.1, E3801.11, and E3803.4. COMMENT REMAINS: Not addressed. Show locations of smoke detectors. Reference IRC Sections R313.1 and R313.1.1. COMMENT REMAINS: Not addressed. Please specify how many lamps of each type are being used for the exterior lighting. Lumens will be calculated by the maximum allowed watts for each fixture that the manufacturer specifies. Reference City of Tucson Outdoor Lighting Code. COMMENT REMAINS: Not addressed. Cross-reference exterior lighting fixtures on the plans with the cut sheets and calculations submitted. Reference City of Tucson Submittal Requirements. COMMENT REMAINS: Not addressed. ENERGY CODE COMMENTS: Reviewed and accepted. ACCESSIBILITY COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
| 09/18/2006 | DROBEY1 | ENGINEERING | REVIEW | Needs Review | |
| 09/18/2006 | DROBEY1 | WWM | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/18/2006 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 09/18/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 09/18/2006 | DELMA ROBEY | REJECT SHELF | Completed |