Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM02715
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2006 | MADARA ENGINEERING | 2ND PARTY REVIEW | REVIEW | Denied | MADARA Engineering, Inc. 4545 E. Shea Blvd. Suite 207, Phoenix, AZ 85028, phone (602) 493-1963, fax (602) 493-1967 Date: August 29, 2006 To: Luis Rojo 4702 S. 9th Ave. Tucson, AZ 85714 Phone: (520) 481-7579 Project name: 880 E. Pennsylvania St. Permit #: TO6-CM02715 Structure: SFR Occupancy: R-3/U Occupant load: 9 Construction Type: V-B Area S.F.: 2218 Project number: 18-6017-02 The first submittal plans for the above referenced project are in the process of Architectural, Structural, Plumbing, Mechanical and Electrical plan review for compliance with the City of Tucson ordinances and applicable codes. Corrections required are noted below. All corrections must be made to the original drawings and new complete and revised sets resubmitted along with a written response to each of the items listed below to facilitate a shorter back-check time. The scope of this review covers Architectural, Structural, Plumbing, Mechanical and Electrical review. These disciplines were checked only to the extent allowed by the documents provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. ARCHITECTURAL COMMENTS Provide the following note: A separate insulation inspection prior to drywall or an insulation certificate will be required at time of final. Ref. IRC Section N1101.3.1. Opening between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inch thick, or shall be 20-minute fire rated doors and shall be maintained self-closing and self-latching. Amendment to IRC Section R309.1. The self latching feature has not been indicated. Appliances located in a garage or carport shall be protected from impact by automobiles. Protection shall be provided by either a floor elevation change with a curb 4 inches high and 3 feet deep, located out of the travel path, or a minimum 3 inch steel pipe bollard installed a minimum of 18 inches below and a minimum of 44 inches above the finished floor in front of equipment. Ref. IRC Section M1307.3.1. Address water heater as it is not a curb, but not out of the impact zone from bumpers / 3’ from front edge of curb or out of vehicular path. Appliances having an ignition source shall be elevated such that the source of ignition is not less than 18 inches above the floor garages. For the purpose of this section, rooms or spaces that are not part of the living space of a dwelling unit and that communicate with a private garage through openings shall be considered to be part of the garage. Ref. IRC Section M1307.3. Address HVAC unit. Indicate the R value of roof and wall insulation. Ref. IRC Section N1101.3. Also specify glazing/door minimum U factor on plans. Coordinate the type and location of upper attic ventilation as Sheet 3 indicates 2 vents (A+B) but Sheet 5 shows 3 vents. Ref. IRC Section R806. STRUCTURAL COMMENTS – Structural portion has been reviewed an approved; PLUMBING COMMENTS Key the notes on Sheet 8 to plan location. Provide a drainage pipe drawing showing all drain, waste and vent piping reflecting all pipe sizes, showing the correct directional flow and providing vents for all fixtures taken off downstream of trap and provide clean out for Kitchen sink. Revise plan showing 1” water supply to show 1 ¼” size. Coordinate plumbing fixture water flow rates listed twice with different figures. MECHANICAL COMMENTS Indicate the “R” value for supply and return air duct insulation. Indicate CFM of Kitchen range hood exhaust and materials, size and route of exhaust duct. Key the notes on Sheet 6 to plan location. Show condensate line for HVAC to point of discharge. Ref. IRC Section M1411.3 and M1411.3.1. ELECTRICAL COMMENTS: Revise panel schedule so that it is indicating all branch circuits installed in dwelling unit bedrooms shall be protected by an arc-fault circuit interrupter(s). Ref. NEC Article 210-12(b), IRC Section E3802.11. Show disconnect for hot water heater. Ref. IRC Table E 4001.5. Denote on plan that fixtures, fitting, boxes and receptacles located in damp or wet locations shall be “listed” for location. Ref. IRC Section E3802. Review circuit 1 notations in Kitchen for correctness and revise call out for disposal to reflect circuit number 1. The revise plans do not show electric service location as previous plans; please clarify intended location of service. Should you have any inquires regarding this letter, please do not hesitate to contact the Plan reviewer at (602) 493-1963. MADARA Engineering for the CITY OF TUCSON By: Michael Hundley Vice-President |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/06/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 09/06/2006 | SUE REEVES | REJECT SHELF | Completed |