Permit Number: T06CM02635
Parcel: 118220550

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T06CM02635
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide an updated joint sewer use aggreement.
2. Provide the size and location of the existing water meter that is serving the three existing buildings on the south side of the lot. and the proposed building. Note that all new residential dwelling units are required to be individually metered, either by the public water supplier or the building owner. If the proposed building is to be privately metered, a reduced pressure backflow prevention assembly will be required at the public water meter.