Permit Number: T06CM02584
Parcel: 11708253B

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM02584
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/27/2006 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Denied November 22, 2006 CITY OF TUCSON - SECOND CHECK
Tucson Appl. No. T06CM02584
Bureau Veritas Job No. 01006-161036

Natasha Taplin
3940 E. San Simeon
Tucson, AZ 85751


Re: Plan Review: Taplin Residence
Address: 250 E. 19th Street

Bureau Veritas North America, has completed a review of the following documents on behalf of the City of Tucson:

1. Plans: Two (2) sets of plans (6 sheets, 1 through 5) no dates or stamps.

2. Structural Calculations: None submitted.

Energy Code Compliance: None submitted.

Miscellaneous Documents: None submitted.


These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC).

Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded.


Sincerely,

Bureau Veritas North America



Shelley Knuffke
ICC Plans Examiner











SK:pc c:/tucson\01006-161036pc2
enclosures

Re: Stories: One
Occupancy R-3
Fire Sprinklers: No
Building Area (sq. ft.): 1584 (livable)


A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code.

B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance.

C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.).


FRAMING PLAN:

Please provide a diagram showing proper hold down and anchor bolt schedule for all footers and braced wall locations.


MECHANICAL PLAN

Please provide a separate Mechanical plan that includes all compete revisions (1-9) from previous comments list.

In addition to 1-9 from the prior list, include a Gas Isometric.


ELECTRICAL:


Provide a complete electrical plan. Designate the location of all required light fixtures, receptacle outlets, power outlets and switches. Show location of all sub panels and show circuit numbers on the plan. Indicate the location of all air conditioning and heating units, air handlers, compressors and disconnects. IRC Sec. R106.1.

If you have any questions regarding the above comments, please contact Shelley Knuffle at (520) 622-9220 between 8:00 A.M. to 5:00 P.M., M-F.
11/30/2006 GERRY KOZIOL WWM REVIEW Denied need to show method/location of connection to public sewer

Final Status

Task End Date Reviewer's Name Type of Review Description
01/08/2007 GERARDO BONILLA OUT TO CUSTOMER Completed
01/08/2007 SUE REEVES REJECT SHELF Completed