Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM02521
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2006 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 04/28/2006 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 04/28/2006 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 05/01/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the utside air calculations to reflect the actual space usage and to correct the arithmetic. 2. Any new flexible duct shall have a minimum of R-5 insulation. |
| 05/01/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. If the specified water heater is not supplied with integral heat traps, provide heat traps on the supply and discharge piping. Reference Section 804.4, IECC 2003. 2. Provide information to show how the outlet temperature of the hot water is to be limited to 110 degrees at the lavatory. Reference Section 804.3, IECC 2003. 3. Show the basis for sizing the water piping. 4. Clarify the piping to the water heater as shown on the water riser diagrm. |
| 05/01/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 05/01/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/02/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T06CM02521 5/2/06 1. Load tabulations for Phases A, B, and C appear to be 15632, 14434, and 15152 VA, respectively, not 13874, 13034, 13752. 2. Total VA and A appear to be 14149 VA, and 136.5A, not 44379VA and 123.2. |
| 05/09/2006 | GERRY KOZIOL | WWM | REVIEW | Approved |