Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T06CM02404
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/04/2006 | GERRY KOZIOL | WWM | REVIEW | Denied | recounted all plumbing / need 8th floor credit evaluation. |
| 08/21/2006 | DANIEL RUSCH | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS for Activity # T06CM02404 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. As of 9-02-04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the 2003 UPC with amendments. All plans should reference these codes. All dimensions and notes shall be consistent on each plan or elevation. FOUNDATION PLANS: 1. I didn't locate foundation schedules S1.01 or S1.03 that you referenced. 2. All exterior doors require a landing or floor at the exterior. Landings must be at least as wide as the doors they serve and 36" in the direction of travel, R311.4.3. 3. Show compliance with termite treatment specified by R320, as amended. 4. Epoxy connections require special inspections. If used, a special inspection request must be included with the permit application. Additionally special inspections will be required for 3000psi concrete and earthwork. FLOOR PLANS: 1. Identify windows requiring safety glazing (within 24" of doorways), R308.4.6. 2. Show the garage floor direction of slope, R309.3. 3. Show hearth size and materials, R1003.10 or R1004.2 STRUCTURAL PLANS: 1. Perimeter wall requires a permit. Walls in excess of 6' shall be designed by a registrant. 2. Justify TJI @ 36' span and statements "double roof joist below roof mounted equipement" and "roof load only". 3. Justify GLB and camber @ line "D". You have identified two and neither one works. 4. Ledger in detail 2/6 should comply with R606.10. 5. Show details for typical non-bearing interior wall conditions (floor and rafter/joist connections & gaps). ELEVATIONS: 1. Indicate all materials used; stucco, concrete block, glass block, roofing system, siding, veneer, etc. 2. Calculate the attic space ventilation area using the correct attic area in compliance with R806.2. Note size and location of all vents needed to comply. 3. Note and size all roofing drains and scuppers for flat roofed areas, R903.4. SECTIONS - DETAILS - MISC. NOTES: 1. Cross-sections shall be accurately cross-referenced to the floor plan and framing plans. 2. Show GluLam beams with 1/2" clearances from masonry, R319.1.4. 3. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c framing, IRC table R702.3.5 footnote d. 4. Show chimney crickets, R1001.17. 5. Joist hangers don't fit joist. 2/6 & 1/7 6. Indicate how R-38 fits into 2x8-joist space. PLUMBING PLANS: 1. Hose bibs require backflow preventers, UPC 603. 2. Provide pressure and temperature relief valve at water heater. T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down, UPC 608.5. 3. Show an upper terminal cleanout at each horizontal drainage pipe greater than 5'(all drains with a sink) UPC 707.4. 4. Show the cleanout size (1-½" for drains up to 2" and 2-½" for drains up to 3") as required by Table 7-6. 5. Show a clean out at the kitchen sink area UPC 707.4 W/ State amendment. 6. Indicate waste pipe sizing throughout. You cannot tie 4" into existing 3" as indicated. ELECTRICAL PLANS: 1. Designate the location and circuit of each light fixture, receptacle, and switch. Provide a panel schedule noting circuit number and breaker & wire size along with a general description. Some missing, some inaccurate. 2. Lights installed over shower or bathtub must be approved for use in wet area, E3903.8. 3. Indicate the location of convenience outlets and light switches for attic heating and air conditioning equipment. Service outlet must be within 25' of equipment. (see E3801.11 and E3803.4) 4. Provide a note indicating only approved outlet boxes shall be used for ceiling fans, E4001.6. 5. Smoke alarms are required outside each separate sleeping area R313.1.2. Additionally, no smoke detector is indicated in guest quarters. 6. At least one GFCI receptacle outlet shall be installed in the garage E3801.9 & E3802.2. 7. An arc-fault circuit interrupter shall protect bedroom outlets including receptacles, lights and smoke detectors, E3802.11. 8. Panel ampacity exceeds service. 9. Indicate over-current protection for feeder circuits. OUTDOOR LIGHTING CODE 1. Full cut-off fixtures have no emittance above the nadir (no deco openings, semi-opaque panels or exposed lamps). Fixtures may be exempt from the total lumen budget if both of the full cut-off FCO style and located under overhangs, OLC 5.1.2. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). 2. Justify why you discount your lumen calculations 75%. 3. Provide cut sheet for fixture and bulb. If you have any questions, please contact your assigned plans examiner DANIEL RUSCH at 791-5550, extension 1113. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/30/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 08/30/2006 | SUE REEVES | REJECT SHELF | Completed |