Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM02191
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/17/2006 | TERRY STEVENS | ZONING | REVIEW | Approved | |
04/17/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
04/17/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
04/17/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
04/17/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | S1. ADDRESS ACCESSIBILITY SHOW ON DRAWINGS WHERE 20% OF PROJECT VALUATION IS SPENT ON ACCESSIBILITY. S2. CLARIFY FINISHES IN TOILET ROOM ie: WAINSCOT? S3. CLARIFY TOILET ROOM : 1. PROVIDE LARGER FLOOR PLAN, EXPLAIN ACCESSIBILITY. 2. PROVIDE CROSS-SECTION THROUGH LAV SHOWING DEPTHS FOR KNEE AND TOE CLEARANCES. S4. PROVIDE 1/8 INCH MINIMUM LETTER SIZE, REF A1 AND A2. |
04/17/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Approved | |
04/17/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise the plumbing riser diagram for rooms 112 and 113 to include the existing sink. 2. Provide an upper terminal cleanout for P-1 in room 113. Reference Section 707.4, UPC 2003. 3. Provide an upper terminal cleanout for P-4. Reference Section 707.4, UPC 2003. 4. Show how the temperature of the hot water supply to the public lavatories is controlled. Reference Section 414.1, UPC 2003 and Section 804.3, IECC 2003. 5. Provide a detail of the water heater installation, including the excess pressure relief, expansion tank, and valves. Reference Sections 103.2.3, 605.5, and 608.3 UPC 2003. 6. Adjust the size of the fonts on the drawings to a minimum of 1/8". |
04/17/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
04/25/2006 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/25/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |