Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T06CM02179
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/22/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1. The City Engineer has approved landscaping within ROW along Golf Links, however street landscape borders along private streets shall be a minimum width of 10 feet. It is to be located on site and measured from the street property line. The landscaping area is extended only to the back of required sidewalks per DS 2-06.3.4.C.1. Revise plan as necessary. 2. All plant material used for landscaping shall be selected from the Drought Tolerant Plant List in Development Standard 9-06.7.0 Exhibit II. Acacia abyssinica is not on the list choose alternate plant material. 3. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1. Additional trees are required. 4. Additional comments may apply. |
| 08/23/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Brian Short DATE: August 23, 2006 BRS Architecture 1313 S Copias Way Tucson, Arizona 85713 SUBJECT: Golf Links Comm. Bldg., 7755 E Golf Links Rd. Site plan T06CM02179 (Second Review) T14S, R15E, Section 29 RESUBMITTAL REQUIRED: Site Plan and Drainage Report. The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. During the first review, I did not notice that sidewalks will be required along the entire length of all street frontages. This includes but not limited to upgrading the existings W/C ramps to meet current code per D.S. 3-01.2.4.3.A. 3. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. Although the scuppers have been added, it appears that the scuppers may not be able to drain into the P.A.A.L. because of the handicap ramp. Drainage Report: 1. The DR has been accepted for site plan purposes only. Final acceptance will be given at the grading plan stage. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax, 7755 E Golf Links Rd. site2 |
| 09/07/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: GOLF LINKS COMMERCIAL BUILDING T06CM02179 Site Plan (2nd Review) TRANSMITTAL DATE: September 8, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Provide note stating that detectable warnings (truncated domes) are required at all handicapped curb ramps per ICC/ANSI A117.1-2003 Section 406.13. Also provide a detail of how the ramps defined by keynote 7 will work i.e. which way do they slope, are flares part of the ramp. D.S. 2-02.2.1.12 2. It is still not clear that delivery trucks will be able to maneuver safely into and out of the loading space. There can be no guarantees that future tenants won't require larger trucks, therefore the design of the loading zone will show how larger vehicles can gain access. Show truck maneuverability for the loading zone. D.S. 2-02.2.1.14. 3. An over the counter review can be provided once the corrections have be made. Call to schedule an appointment. If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180. C:\planning\site\t06cm02179.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 09/11/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Denied | see zoning comments |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/04/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 10/04/2006 | SUE REEVES | REJECT SHELF | Completed |