Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T06CM02179
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/02/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Street landscape borders are required along Tree Moss Ave. and Roget Dr. Identify streets on landscape plan. A street landscape border, per LUC 3.7.2.4 is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress.. 2. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the (future) MS&R right-of-way line as determined by Sec. 2.8.3.4. Dimension street landscape borders accordingly. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee. 3. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g 4. Add note to landscape plan: All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment for landscaped areas. 5. Additional comments may apply. |
| 05/03/2006 | ANDREW CONNOR | NPPO | REVIEW | Approved | Exception |
| 05/19/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Brian Short DATE: May 23, 2006 BRS Architecture 1313 S Copias Way Tucson, Arizona 85713 SUBJECT: Golf Links Comm. Bldg., 7755 E Golf Links Rd. Site plan T06CM02179 (First Review) T14S, R15E, Section 29 RESUBMITTAL REQUIRED: Site Plan and Drainage Report. The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. A plan clearly marked "Site Plan" for review and record purposes. 3. Please provide property description per D.S. 2-02.2.1.3. 4. Please label lot dimensions and bearings per D.S. 2-02.2.1.5 5. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 6. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 7. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 8. Show Site plan number on all sheets per D.S. 2-02.2.1.29. 9. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. 10. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 11. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.. 12. Add note: "Depress all landscaped areas 6" maximum for water harvesting". 13. "A separate grading permit will be required for this project. Submit 4 sets of grading upon completion and submittal of a grading permit application. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans". Drainage Report: 1. The DR has been accepted for site plan purposes only. Final acceptance will be given at the grading plan stage. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/7755 E Golf Links Rd. site |
| 06/06/2006 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | 1) The minimum required text size for microfilming purposes is 12 point (0.12"). Revise on all sheets the lettering and dimensions which do not meet this minimum standard. 2) Revise the legal description to be correct and specific and to include that the site is the westerly 130.99 feet of Le Mirador recorded in Book 37/Page 82 of Maps and Plats. DS 2-02.2.1.A.2 3) Add the information given under the "Project Description" heading on sheet G0.01 to the parking calculations on the same page. If one of the tenant spaces is to be restaurant as stated in the project description, add this information to the calcs. DS 2-02.2.1.A.31 4) Add the LUC restriction that the personal service use is subject to. In the C-1 zone the proposed personal service use is subject to Sec. 3.5.4.13.A, which states that laundry facilities will not exceed 3,000 square feet of floor area. Also, per comment 3 above, if a portion of the building is to be restaurant add the applicable restrictions (subject to Sec. 3.5.4.6.A. and .C). LUC 3.5.3.2.A.12 & .7 5) Add a general note stating that the project is subject to LUC 2.8.3, Major Streets & Routes Setback Zone and LUC 2.8.4. Gateway Corridor Zone. 6) Parked vehicles may not overhang property lines. For the northernmost parking space, dimension the overhang area in front of the space to demonstrate that there is at least 2-1/2 feet distance available between the parking space and the property line to allow for vehicle overhang. DS 3-05.2.3.C.1 7) It is not clear that delivery trucks will be able to maneuver safely into and out of the loading space. Show truck maneuverability for the loading zone on sheet A1.01 as was done for the dumpster area. Where PAALs are used as access lanes for refuse collection or loading zones, a minimum unobstucted radius of eighteen (18) feet is required at the PAAL intersection. DS 3-05.2.1.C.3.a 8) Provide the maximum slopes of handicap parking access ramps and aisles. Indicate the use of truncated domes on accesible ramps and sidewalk grade changes as required. ANSI |
| 06/07/2006 | PETER MCLAUGHLIN | ZONING HC SITE | REVIEW | Denied | See zoning review comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/12/2006 | GBONILL1 | OUT TO CUSTOMER | Completed |
| 06/12/2006 | SUE REEVES | REJECT SHELF | Completed |