Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - T06CM01814
Review Name: REVISION - - 1ST
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | December 29, 2006 City of Tucson Development Services 201 N. Stone Avenue Tucson, AZ 85701 RE: ARCO REMODEL-IRVINGTON REVISION – 1ST REVIEW CITY OF TUCSON LOG NO. T06CM01814-R WILLDAN PROJECT NO. 13881-6091 The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Chris Kiel. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms N/A N/A N/A N/A N/A N/A ELECTRICAL COMMENTS: Sheet E-1 Please provide the previously approved sheet E-1 per section 106.1.1 of the 2003 IBC. The current submittal for sheet E-1 does not appear to contain the same information. Sheet E-2 Please coordinate the fault current calculations with the panel labels per section 106.1.1 of the 2003 IBC. Please coordinate the load summary with the revised loads associated with panel C per section 106.1.1 of the 2003 IBC. Please coordinate the panel B label with the new keynote #1 per section 106.1.1 of the 2003 IBC (65K/10K vs. 42K/10K). Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/17/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 01/17/2007 | SUE REEVES | REJECT SHELF | Completed |