Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM01782
Parcel: 123052370

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM01782
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/19/2006 BROWN & ASSOCIATES 2ND PARTY REVIEW REVIEW Denied Brown & Associates
177 N Church Avenue, Suite 311
Tucson, Arizona 85701
Office (520) 882-4735 Fax (520) 882-5412


2nd - Review
RESIDENTIAL PLAN REVIEW

Client: City of Tucson Reviewer: Mike Brown

Project: 2040 N. Norton Ave. #2 Permit #: T06CM01782

Date: May 16, 2006 Brown & Associates #: 85701-6217

_______________________________________________________________

2003 International Residential Code, 2003 UPC with State Amendments, Outdoor Lighting Code; 2003 IBC applies for engineered structural designs.

Residence Area: 1585 Exist S.F. Number of Floor Levels: 2
Garage Area: TBD S.F. Additional # of Elevation Options: 1
Porch/Stair/Deck Area: TBD S.F. Building Wall Construction: Rastra Block
Basement Level Area: n/a S.F. Building Grade Floor Construction: S.O.G.
Guest House Area: 1140 S.F. Building Roof Construction: Wood
Guest House Construction: V-B Elevated Floor Construction: Wood
Remodel Area: n/a S.F.


NOTE: THE FOLLOWING ITEMS NEED TO BE CORRECTED PRIOR TO RESUBMITTING YOUR PLANS FOR APPROVAL. RETURN ALL SUBMITTAL PLANS AND DOCUMENTS WITH YOUR REVISED SUBMITTAL PLANS AND DOCUMENTS. .
X Revise Plans for Compliance
IRC Section R105.3.1



ARCHITECTURAL PLAN COMMENTS


X 1. Indicate the scale of each drawing found on the plans. Due to repetitive plan reproduction the documents provided are not legible. The City of Tucson requires that all plans be provided with text that is not less than 1/8 inch in height. There appear to be dimensional differences between various plans, elevations and details. Provide revised clearly legible documents upon resubmittal. IRC Section R106.1.1.

X 2. There shall be no openings in the common wall between a garage and any sleeping room. The garage shall be separated from the residence and its attic area by not less than 1/2-inch gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8-inch Type X gypsum board or equivalent. Where the separation is a floor-ceiling assembly, the structure supporting the separation shall also be protected by not less than 1/2-inch gypsum board or equivalent. In buildings protected by an automatic fire sprinkler system, including the private garage, the separation shall be permitted to be limited to a minimum 1/2-inch gypsum board applied to the garage side. Amendment to IRC Section R309.1 and R309. There appears to be a master bedroom addition shown with openings into the garage. Revise plans as necessary.


MODEL ENERGY CODE COMMENTS

X 1. Provide on the architectural drawings a calculation to determine the percentage of glazing in the gross area of the exterior walls. Calculations to verify compliance with the jurisdiction’s adopted Energy Conservation Code are required when the glazing area of a detached dwelling exceeds 15-percent of the gross area of the exterior walls. IRC Section N1101.2.1, N1102.1. Provide information on plans.


STRUCTURAL FOUNDATION PLAN COMMENTS:

X 1. The proposed structure does not meet the prescriptive design requirements of IRC Section R404.4. Provide structural engineering calculations sealed, signed and dated by an Arizona Registrant. The registrant shall also seal, sign and date the plans. Provide two separate bound sets of calculations.


ELECTRICAL PLAN COMMENTS:

X 1. Receptacles shall be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width. IRC Section E3801.2.1. Revise receptacle outlet spacing in the living room.


OUTDOOR LIGHTING CODE:

X 1. Provide catalog cuts of all outdoor lighting fixtures identifying fixture shielding or non shielding installation conditions and output lumens for each outdoor lighting fixture. Provide cutsheets as previously requested.

X 2. Provide on the drawing appropriate tabular calculations that identify Outdoor Lighting Code site designation, total site area, allowable lumens per Table 5.1, conditions for installation of outdoor lighting fixture type, total lumens allowed at the site, maximum unshielded lumens at the site, and the actual installed lumens at the site for each fixture type. Requirements for this can be found on the jurisdiction’s web site. Provide information on plans.




Sincerely,

BROWN & ASSOCIATES



Michael J. Brown, C.B.O. President
MB:jah

Final Status

Task End Date Reviewer's Name Type of Review Description
05/31/2006 JMORALE1 OUT TO CUSTOMER Completed
05/31/2006 SUE REEVES REJECT SHELF Completed