Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM01710
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/28/2006 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 03/28/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | The minimum insulation for ducts located in unconditioned spaces within the building envelope is R-5 (installed). Reference Section 803.2.8, IECC 2003. |
| 03/28/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide the listing information for the proposed 2-way cleanout. Reference sections 707.4 and 707.6, UPC 2003. 2. Provide a detail of the water heater re-installation, including the excess pressure relief (including size, route, and termination) expansion tank, and valves. Reference Sections 103.2.3, 605.5, and 608.3 UPC 2003. 3. Show that the position stops on the mixing valves for the showers are to be adjusted to supply a maximum water temperature of 120 degrees Fahrenheit. |
| 03/28/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/28/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 03/28/2006 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 03/29/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 04/04/2006 | CAGUILA1 | WWM | REVIEW | Needs Review | |
| 04/04/2006 | CAGUILA1 | BUILDING-COMMERCIAL | REVIEW | Needs Review |