Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM01512
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/20/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Approved | |
03/20/2006 | GERRY KOZIOL | WWM | REVIEW | Approved | |
03/20/2006 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
03/21/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a riser diagram showing how the water, waste, and vent piping is to be modified. 2. Provide temperature controls for the lavatory per Section 414.1, UPC 2003 and Section 804.3, IECC 2003. |
03/21/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | S1. PROVIDE PROJECT VALUATION. S2. USE CURRENT CODES SEE WEBSITE WWW.TUCSONAZ.GOV/DSD . S3. PROVIDE STRUCTURAL DESIGN AND DETAILS FOR STOREFRONT INCLUDING FASTENER TYPE SIZE SPACING/NUMBER AND ATTACHMENT TO EXISTING STRUCTURE, SPECIFY MATERIALS . S4. FULLY DIMENSION TOILET ROOM INCLUDING SIDE WALL TO LAV OF 60" MIN PER ANSI A117.1-2003ed. S5.ADDRESS OVERAL ACCESSIBILITY FOR EXISTING BUILDING 20% REQUIRED TO BE SPENT ON ACCESSIBILTY, PROVIDE ESTIMATE ON DRAWINGS PER 2003 IBC CHAPTER 11 AND 34 AND ANSI A117.1. S6. CLARIFY EXITING AND OCCUPANT LOADS FOR SPACES/ ROOMS IF SECOND EXIT REQUIRED THROUGH STORAGE AREA PROVIDE CORRIDOR. S7. MINIMUM LETTER SIZE ON SUBMITTAL TO BE 1/8 INCH ALL CAPITALS. S8. PROVIDE COMPLETED CODE REVIEW CHECKLIST. |
03/21/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
03/21/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
03/21/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the design of the HVAC for the restroom to prevent recirculation of the air supplied to the restroom. Reference Section 402.3.1(3), IMC 2003. 2. New ductwork and flexible duct shall have a minimum insulation of R-5 in unconditioned spaces. |
04/04/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | T05CM01512 3/21/06 1. Sheet P.0 calls for a 3.5 KW 208V WH. Please provide electrical power. 2. City of Tucson currently enforces the 2003 IECC not 2001. http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html. |