Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T06CM01434
Parcel: 12504079A

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM01434
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/24/2007 DAVE MANN FIRE REVIEW Approved
05/29/2007 PATRICIA GILBERT ENGINEERING REVIEW Approved
06/08/2007 ANDREW CONNOR NPPO REVIEW Approved
06/08/2007 ANDREW CONNOR LANDSCAPE REVIEW Approved
06/22/2007 HEATHER THRALL ZONING HC SITE REVIEW Denied the site plan is in compliance with ANSI requirements, this note is just to remind the reviewer to stamp the plan with the handicapped parking stamp once the site plan can be approved.

note that building codes may require further handicapped parking and access to the parking garage
06/22/2007 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: T06CM01434, 1900 E. Speedway Boulevard
New Hotel Building, Site Plan, 5th review

TRANSMITTAL DATE: June 25, 2007

COMMENTS: please contact me for an appointment to address the following:.

1. Please note, a lot combination covenant is still needed for the hotel site - all three lots. Provide covenants and recordation receipt ( these forms are on our website at www.tucsonaz.gov/dsd under forms) Provide a note on the plan listing the lot combination covenant was recorded, with docket/page.

2. Clarify the number of rooms on site - I see differing numbers for parking calculations and for the number of rooms. Clarify if there is extra parking on this site then.

3. Please clarify if the parking garage facility is to be newly reconstructed and show where replacement columns will be installed. Beware that columns should be installed so as not to interfere with exiting/entering parking spaces.

4. The parking spaces at the east side of the parking garage, at 80 degree, do not have a sufficient PAAL width behind them. They require a 24' wide PAAL, or change the angle of the parking spaces to fit with the 18' wide PAAL provided.

5. Within the parking garage: please clarify why pedestrian access is not provided to the "clean room" when there are pedestrian openings right near the parking.

6. Please clarify whether elevators are in this parking garage. I see notes stating "lift" - but not specifically for an elevator.

7. Be advised, building codes may require further handicapped parking to be provided in the parking garage, per Chapter 1106 of the IBC. Please contact a structural reviewer at DSD for further advisement.

8. Depending upon the responses provided, further review comments may be forthcoming. Should you have questions on this review, please contact me via email at Heather.Thrall@tucsonaz.gov or at 791-5608x1156.

If you have any questions about this transmittal, please call (520) 837-4951.

HCT C:\planning\site\DSD\T06CM01434 1900 e speedway 5.doc

THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
06/25/2007 GERARDO BONILLA OUT TO CUSTOMER Completed
06/25/2007 SUE REEVES REJECT SHELF Completed