Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM01263
Parcel: 13018001B

Address:
3940 E 29TH ST

Review Status: Completed

Review Details: OTHER

Permit Number - T06CM01263
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/09/2006 JASON GREEN ENGINEERING REVIEW Approved DATE: June 12, 2006
SUBJECT: Tenant Improvement: Remodeling of Kitchen- Engineering Review
ADDRESS: 3940 E 29th Street, Tucson Arizona 85712
PROPERTY OWNER: Sunni Phillips
LOCATION: T14S R14E Section 22 A portion of Parcel 130-18-001B, Imperial Gardens E96' of W296' of Blk 1
REVIEWER: Jason Green, CFM
ACTIVITY NUMBER: T06CM1263

SUMMARY: The TI plans and building review documents, described as Proposed Kitchen Hood for Alfie's Pub, were received and reviewed by Engineering Division. The Floodplain Use Permit application, T06OT01469, will be issued and is to include valuation of the improvement and location map, for the purpose of tenant improvements to an existing, non-conforming floodprone structure. Engineering Division recommends approval of the Floodplain Use Permit.
CONDITIONS OF PERMIT:

1) The associated improvements are with permit activity number T06OT01469 (Floodplain Use Permit) and T06CM01263 (TI plans).
2) Any improvements to the structural building for this project are considered a substantial improvement to an existing floodprone structure if the value of this new improvement is 50% or more than the value of the existing structure in present day value. If the project is determined to be a substantial improvement, and, if it is determined that the lowest floor elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for floodproofing will be required and shall conform to City of Tucson floodplain development requirements.
3) Cumulative values shall be accounted for the building structure, so that tracking of the 50% status is current. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Floodplain and Erosion Hazard Management.
4) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
5) This permit is specific to the improvements specified as the construction of the interior improvements for Alfie's Pub as shown on this plan. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.
6) Copies of the improvement plans/permit documents shall be kept in a readily accessible location on site at all times.


If you have any questions, I can be reached at 791-5550, extension 1189.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
06/14/2006 SUE REEVES APPROVAL SHELF Completed
06/14/2006 JMORALE1 OUT TO CUSTOMER Completed