Review Date Reviewer's Name Type of Review Description Status Comments
06/07/2006 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Approved
06/07/2006 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
06/07/2006 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
06/12/2006 CHRISTY FOREMAN BUILDING-COMMERCIAL REVIEW Denied CITY OF TUCSON DEVELOPMENT SERVICES
STRUCTURAL REVIEW COMMENTS

DATE: 6/13/06
ACTIVITY NUMBER: T06CM01160
PROJECT NAME: JOHN WESLEY MILLER COMPANIES
PROJECT ADDRESS: 63 E. CONGRESS
ARCHITECT / ENGINEER: ABA Architects
PROJECT REVIEWER: Christy Foreman


TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS.


1) Provide note on drawings that accessible route is fully compliant.

2) Change of occupancy address section 3406. Justification provided would need a approved building appeal. Door into other tenant space should be eliminated.

3) Occupant load of 19 requires one accessible men's restroom and one accessible woman's restroom. Occupant load is based on sq. footage of tenant space per table1004.1.2. The IBC 2003 does not allow occupant load to be reduced.

4) Justify that existing roof can carry additional loads of solar panels. Provide existing roof framing plan.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/14/2006 SUE REEVES APPROVAL SHELF Completed