Permit Number: T06CM00938
Parcel: 12507351A

Address:
2227 E 7TH ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T06CM00938
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/24/2006 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Denied March 1, 2006 CITY OF TUCSON - FIRST CHECK
Tucson Appl. No. T06CM00938
LP2A Job No. 2060161.016

City of Tucson
201 N. Stone Ave. 1st Floor
Tucson, AZ 85701

Re: Plan Review: Zaer SFR Addition/Remodel
Address: 2227 E. 7th Street

Linhart Petersen Powers Associates (LP2A), a Bureau Veritas Company, has completed a first review of the following documents on behalf of the City of Tucson:

1. Plans: Two (2) sets of plans (7 sheets 1 through 7) with no dates and no stamps.

2. Truss Calculations: None provided.

Structural Calculations: None provided.

Energy Compliance: None provided.


These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC).

Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded.


Sincerely,

LINHART PETERSEN POWERS ASSOCIATES
A Bureau Veritas Company




Randy McCoy, Senior Plans Examiner
ICC Plans Examiner







RM:pc c:/tucson\2060161.016pc1
enclosures






Zaer SFR Addition/Remodel City of Tucson - First Check
2227 E. 7th Street LP2A Job No.:2060161.016
March 1, 2006 Page


Re: Stories: One
Fire Sprinklers: No
Building Area (sq. ft.): 178 (livable)
367 (porch)


A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code.

B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance.

C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.).


ARCHITECTURAL COMMENTS:

Glass is hazardous areas shall be safety glass. Specify on applicable floor plans and elevations. IRC 308.4. Tub area.

Factory built fireplaces (zero-clearance) shall be listed by an approved listing agency. Specify make and model number and provide the approval number of the resting agency. IRC Section R1004.

Note dimension that the fireplace chimney must terminate a minimum of 2 feet above any point of the roof within 10 feet measured horizontally. Include chimney on applicable elevations. IRC Table R1001.6. Sheet 3.

Porch valley built up beam (3) 2x6 shall require structural beam calculations/engineering. IRC106. Sheet 5.


MECHANICAL, ELECTRICAL AND PLUMBING COMMENTS:

Provide a gas isometric with length of line (horizontal and vertical) to each appliance, BTU demand of each appliance, size of each branch, total demand and size of meter. IRC106. Sheet 4.


If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/06/2006 GBONILL1 OUT TO CUSTOMER Completed
03/06/2006 SUE REEVES REJECT SHELF Completed