Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T06CM00856
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/07/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 09/08/2006 | ANDREW CONNOR | NPPO | REVIEW | Approved | Exception |
| 09/08/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 09/20/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Denied | TO: Thomas L. Fraser DATE: September 25, 2006 FROM: Suzanne Bohnet, CFM Engineering Division SUBJECT: 1830 W. Prince Rd. Bluewater Marine Site plan T06CM00856 (Third Review) RESUBMITTAL REQUIRED: Site Plan and Drainage Report. The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please include a response letter to the comments along with the corrected copies of the SP and GP with your next submittal. Site Plan: 1. Please provide additional spot elevations to verify the drainage flow. 2. Please add the access ramps for the right-of-way sidewalk at the driveway apron. 3. Please clarify the face of future curb. 4. Please revise the future sight visibility triangle (SVT) to show a stem of 20 feet from the face of future curb. 5. On the north side of the building, the pedestrian use area (i.e., sidewalk) is flush with the vehicular use area, per comment response #8 from the Second Review. Please provide truncated domes the length of the sidewalk where there is no vertical separation between the pedestrian use and the vehicle use areas. Drainage Report: 1. Please review and revise as necessary the data provided in the Storage-Discharge Relationship and the Routing Tables for the 2-year, 10-year and 100-year storm events, per our phone conversation this day. 2. There is a typographical error on page 2 of the Drainage Report that gives the elevation datum as NAVD '88 for the finished floor elevation instead of NGVD '29. Please do not hesitate to contact me with any questions. Thank you, Suzanne Bohnet, CFM Engineering Associate (520) 791-5550 x1188 office Suzanne.Bohnet@tucsonaz.gov |
| 09/29/2006 | HEATHER THRALL | ZONING HC SITE | REVIEW | Approved | |
| 09/29/2006 | HEATHER THRALL | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/05/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 10/05/2006 | SUE REEVES | REJECT SHELF | Completed |