Permit Number: T06CM00805
Parcel: 10712171A

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM00805
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/08/2006 SUZANNE BOHNET ENGINEERING REVIEW Denied DATE: November 13, 2006
FROM: Suzanne Bohnet, CFM
Engineering Division

SUBJECT: 375 W. Blacklidge Dr.
Oracle 21 Homes
Site Plan T06CM00805 (Third Review)

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan and Grading Plan cannot be approved as submitted. Please include a response letter to the comments below along with the corrected copies of the Site Plan with your next submittal.

Site Plan:
1. Please provide the sight visibility triangle for the intersection of Balboa and Blacklidge, measuring the 20' stem on Balboa and using the near side measurement of 180' for Blacklidge.
2. Please note that the sidewalk for right-of-way (ROW) sidewalks is a minimum 5'. Please revise the width of the ROW sidewalk on Blacklidge to 5'.
3. With regards to the above comment, please change the dimension of the sidewalk on Detail 2, Sheet 3 to 5'.
4. Please provide the Docket and Page of the Drainage Easement noted as the outlet drain for Basin No. 2.
5. Please call out the areas to be used for water harvesting on the Site Plan, either by Keynote or labeled as such.
6. Please clarify the purpose of the arrow pointing out towards Balboa with the Keynote No. 6, which calls out a 20' fire lane driveway - no exit.

Grading Plan:
1. Please provide the general dimensions of the basins.
2. It appears there is a 6" curb on the eastside of Basin No. 2, blocking the drainage from reaching the basin. Please clarify and/or label as needed.

Drainage Report:
1. Please revise the calculations for the determination of the 5-year threshold retention requirements using the 5-year weighted runoff coefficients rather than the 100-year coefficients.
2. Please revise the volume calculations of the basins to ensure retention of the 5-year volumetric difference between pre- and post-development.

Please do not hesitate to contact me with any questions.

Thank you,
Suzanne Bohnet, CFM
Engineering Associate
(520) 791-5550 x1188 office
Suzanne.Bohnet@tucsonaz.gov
11/14/2006 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens FOR: David Rivera
Lead Planner Principal Planner

PROJECT:T06CM00805
375 W. Blacklidge Dr.
Townhouses? (Apartments)
Site Plan

Transmittal date: 3rd Review 11/14//06

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The lot reconfiguration information provided has not been completed. The lot reconfiguration must be finaled by the City of Tucson. To final the documents, provide a copy of the legal description, the approved "ok to record" plot plan, address certificate, and recording docket and page for each individual lot. Provide a copy of the plot plan for your records, which will be signed off by zoning staff. Bring all of the above documents to the zoning counter here at DSD in order to complete the lot reconfiguration.

Remove from the site plan the old lot lines and indicate the new lot lines for parcels 2 and 3.


2. Based on changes made to the site plan and responses to the above comments further comments may be forth coming.


If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.
11/14/2006 TERRY STEVENS ZONING HC SITE REVIEW Approved
11/22/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Portions of the street landscape border appear to be inappropriate size to facilitate the required coverage. Verify for each plant type(s) the expected coverage.

2. According detail # 12 included on Sheet 4 of 5 of the site plan the entire drainage swale will be rip-rapped. Detail how plantings will be incorporated in these areas.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/01/2006 FSANCHE1 OUT TO CUSTOMER Completed