Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM00669
Parcel: 13502007C

Address:
1441 S WILMOT RD

Review Status: Completed

Review Details: SITE

Permit Number - T06CM00669
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/06/2006 JIM EGAN FIRE REVIEW Approved
02/22/2006 ANDREW CONNOR LANDSCAPE REVIEW Passed
02/22/2006 ANDREW CONNOR NPPO REVIEW Passed
03/24/2006 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: T06CM00669
1441 S. Wilmot, Jim Click Ford Paint Booth Addition
Site plan

TRANSMITTAL DATE: March 30, 2006

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This project was reviewed for full code compliance under the assumption that cumulative building expansions amount over 25% from the last full code compliant site plan approval. The following comments apply, however, should further analysis render a history and expansion clarification under 25%, a revision to the comments will be issued.

2. Per DS 2-02.2.1.2, provide legal description for site. Note that the city mapping systems shows the address 1441 S. Wilmot as one lot, not three as is shown on the plan. If a lot combination has occurred, provide lot combination forms and covenants recorded with the Pima County Recorder's Office. Note, further comments may be forthcoming.

In addition, an alley is shown north of the subject site. Per city maps, this area is not an alley, but a privately owned parcel. Revise alley notation, in addition, aerial photographs show access is provided and use of this adjacent parcel by Ford. Please provide copies of the use and access agreement - and any documentation that the City of Tucson has approved this arrangement. Note, further comments may be forthcoming.

3. Per DS 2-02.2.1.5, provide dimensions/curvature data and bearings for all lot lines.

4. Per DS 2-02.2.1.6, provide all building heights and dimensions.

5. Per DS 2-02.2.1.8, clarify customer/employee parking areas (appears some customer/employee parking near entrances/buildings) and provide dimensions for parking spaces, access PAAL and entries to site. Clarify with arrows any vehicle circulation areas - other than display parking.

Provide parking calculations.

Clarify where handicapped parking is on site, with dimensions, signage and access aisle.

6. Per DS 2-02.2.1.8, clarify bicycle parking area, amount and typical detail drawings.

7. Per DS 2-02.2.1.10, provide sight visibility triangle areas.

8. Per DS 2-02.2.1.12, clarify location of handicapped access ramps, provide typical detail drawings. Note, truncated domes (early warning systems) are required to be installed on all handicapped ramps.

9. Per DS 2-02.2.1.12, clarify pedestrian access to all buildings on site from the street. See DS 2-08.

10. Per DS 2-02.2.1.13, call out any proposed free-standing lighting/signage with specs.

11. Per DS 2-02.2.1.14, call out any loading zones with dimensions, striping, etc. See LUC 3.4.5.3. for details.

12. Per DS 2-02.2.1.19, as Wilmot is a Major Streets and Routes, call out the centerline, future curb location and related dimensions.

13. Per DS 2-02.2.1.20, call out any easements, type, and recording information, if applicable.

14. Per DS 2-02.2.1.28, call out the zoning of adjacent parcels.

15. Per DS 2-02.2.1.32, call out refuse location and access.

16. Per DS 2-02.2.2.A.2, provide the total floor area ratio and lot size in square feet. The floor area ratio calculations should be presented in a cumulative, history listing with dates of expansion.

17. Please be advised, depending upon the responses provided, further review comments may be forthcoming. Should you have any questions on this review, please contact me at Heather.Thrall@tucsonaz.gov or at 791-4541x1156.


If you have any questions about this transmittal, please call (520) 791-5608.

HCT C:\planning\site\DSD\T06CM00669 1441 s wilmot.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
03/31/2006 HEATHER THRALL ZONING HC SITE REVIEW Denied See zoning review comments please.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/11/2006 SUE REEVES OUT TO CUSTOMER Completed
04/04/2006 SUE REEVES REJECT SHELF Completed