Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM00537
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/26/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T06CM00537 .. 4145 N STONE AVENUE #102 .. PHOTOVOLTAIC SYSTEM (MODEL T05-M0242) .. DGL ..1ST REVIEW .. 1/26/06 .. S1. The Building Permit-T03CM02739, for this structure has expired and this Building Permit- T06CM00537, can not be approved until the expired Building Permit-T03CM02739, has been resolved, per the 1997 Uniform Administrative Code Section 303, see expiration letter: (METRO PERMIT EXPRESS, INC 1010 N ALVERNON WY TUCSON AZ 85711 Dear Applicant: This notice is being sent to let you know that our records indicate that the below referenced plan expired on 12/06/2003 . Activity Number: T03CM02739 Address: 4145 N STONE AV TUCFl: #100 4145 N STONE AV TUCFl: #101 4145 N STONE AV TUCFl: #102 4145 N STONE AV TUCFl: #103 Description of Work: NEW:CONDOS In accordance with the Administrative Code you may apply (in writing) for a one-time plan review extension. If granted, the one-time plan review extension would be for 180 days from the original expiration date (see above). To request a plan extension complete the form on the back of this document and return it to City of Tucson Development Services Department, Attn: Plan Extensions, P.O. Box 27210, Tucson, AZ 85726, or fax it to (520) 791-4340. If you prefer, you can fill out the Extension Request form on line (this feature requires Adobe Acrobat Reader), and send it electronically to DSD_PlanExtensions@tucsonaz.gov. You may obtain the form by accessing the DSD web site at www.cityoftucson.org/dsd, select Forms, Fees & Maps, select Forms and Applications, and then select Extension Request Form. Please allow two (2) workdays for a response to your request. Failure to renew the plans or to pick them up from our office within 15 working days, from the date of this letter, will result in the plans being destroyed. If you have already received an extension on these plans or received a permit under this activity number, after the date of this letter, please disregard this notice. Construction without properly issued permits could result in a notice of violation being issued, or the withholding of the certificate of occupancy for this project. If you have any questions, please call 791-5550, press "0" (zero) and ask for Plan Extensions. Thank You. Development Services Department.) S2. Provide the correct structural calculations and drawings from the Structural Engineer, Building #5 is a TYPE II Building not a TYPE I Building as shown on structural calculations and S2.1.4. S3. Provide overall dimension of panel sections on layout plan. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
| 02/06/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/13/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 02/13/2006 | SUE REEVES | REJECT SHELF | Completed |