Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM00375
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/18/2006 | BROWN & ASSOCIATES | 2ND PARTY REVIEW | REVIEW | Denied | Brown & Associates 177 N Church Avenue, Suite 311 Tucson, Arizona 85701 Office (520) 882-4735 Fax (520) 882-5412 3rd - Review RESIDENTIAL PLAN REVIEW Client: City of Tucson Reviewer: L. Pudvah Project: Mendoza Addition Permit #: T06 CM00375 Date: 18 May 2006 Brown & Associates #: 85701-6212 _______________________________________________________________ 2003 International Residential Code, 2003 UPC with State Amendments, Outdoor Lighting Code; 2003 IBC applies for engineered structural designs. Residence Area: S.F. Number of Floor Levels: 1 Enclose Carport Area: 254 S.F. Additional # of Elevation Options: n/a Porch/Stair/Deck Area: n/a S.F. Building Wall Construction: Wood/Masonry Basement Level Area: n/a S.F. Building Grade Floor Construction: S.O.G. Guest House Area: n/a S.F. Building Roof Construction: Wood Guest House Construction: n/a Elevated Floor Construction: n/a Add Bathroom Area: 55 S.F. NOTE: THE FOLLOWING ITEMS NEED TO BE CORRECTED PRIOR TO RESUBMITTING YOUR PLANS FOR APPROVAL. RETURN ALL SUBMITTAL PLANS AND DOCUMENTS WITH YOUR REVISED SUBMITTAL PLANS AND DOCUMENTS. . Highlighted comments are in response to the applicant’s response and resubmittal. Revise Plans for Compliance IRC Section R105.3.1 STRUCTURAL FOUNDATION PLAN COMMENTS: 1. Provide a continuous exterior footing at the enclosed carport and indicate pressure treated plate and anchor bolt requirements. IRC Chapter 4. Anchor bolts for wood sill plates shall be ½-inch diameter with a minimum embedment of 7-inches into the new cast in place concrete footing. All footings shall be clearly dimensioned and depicted to be bearing not less than 12-inches below undisturbed grade. R403.1.6, R403.1.4 STRUCTURAL FRAMING PLAN COMMENTS: 1. Identify and specify structural sheathing for walls, floors and roofs. R503, R604, R803 It is not clear what if any structural sheathing is being installed under the new siding. A weather resistive building paper must be specified to protect the interior of the building. The new end wall must be shown to meet the requirement for braced wall shear panels. The new end wall shall be sheathed with not less than ½ -inch OSB or wood plywood and nailed as required. R602.10.1.1 2. It is not clear what is suppose to be holding up the existing 4x8 over the new window in the enclosed carport. All structural member sizes shall be shown on a dimensioned plan that identifies and depicts the length of member spans, spacings, location and sizes of all rafters, headers, posts and beams. IRC 106.1.1 Sections R602.7, R603.9, R606.9. It appears that an appropriate header beam and jack studs are required to support the end reaction for the existing roof beam which is shown over the new window. Review and clarify design. R502.5 3. Identify that all code required nailing to comply with IRC Table R602.3(1). Sincerely, BROWN & ASSOCIATES Michael J. Brown, C.B.O. President MB:jh |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/30/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |
05/30/2006 | SUE REEVES | REJECT SHELF | Completed |