Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T06CM00243
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/10/2006 | SEPTIC APPROVAL | WWM | REVIEW | Needs Review | |
| 02/14/2006 | BROWN & ASSOCIATES | 2ND PARTY REVIEW | REVIEW | Denied | Brown & Associates 177 N Church Avenue, Suite 311 Tucson, Arizona 85701 Office (520) 882-4735 Fax (520) 882-5412 RESIDENTIAL PLAN REVIEW Client: City of Tucson Reviewer: L. Pudvah Project: 9231 East Old Spanish Trail Permit #: T06CM00243 Date: 14 Feb 2005 Brown & Associates #: 85701-6209 _______________________________________________________________ 2003 International Residential Code; 2003 UPC with State Amendments; Outdoor Lighting Code; 2003 International Building Code. Residence Area: S.F. Number of Floor Levels: One Garage Area: 576 S.F. Number of Elevation Options: n/a Porch Area: 399 S.F. Building Wall Construction: masonry Basement Level Area: n/a S.F. Building Grade Floor Construction: S.O.G. Guest House Area: 2105 S.F. Building Roof Construction: wood Guest House Construction: n/a Elevated Floor Construction: n/a NOTE: THE FOLLOWING ITEMS NEED TO BE CORRECTED PRIOR TO RESUBMITTING YOUR PLANS FOR APPROVAL. RETURN ALL SUBMITTAL PLANS AND DOCUMENTS WITH YOUR REVISED SUBMITTAL PLANS AND DOCUMENTS. . X Revise Plans for Compliance IRC Section R105.3.1 GENERAL REQUIREMENTS: X 1. Construction details provided for Building Safety approval should be represented and detailed on the drawings and not specified by code reference only. CODE section references only are not acceptable when specific construction details are needed to convey and distinguish what it is the constructor is suppose to actually supply and install. R106.1.1 X 2. All corrections to drawings shall be delineated as a dated “clouded delta” revision number on each plan or detail that is revised. Revised drawings shall be submitted as prints of original tracings or masters that have been revised. IRC Section R105, R106 ARCHITECTURAL PLAN COMMENTS X 1. Locate on the plans, mark and identify the size, type and other requirements for all exit and exit access doors. R106.1.1, R308, R309.1, R311.4 X 2. Note on the plans that: “All egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort”. R311.4.4 X 3. Openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8-inch thick, or shall be 20-minute fire-rated doors and shall be maintained self-closing and self-latching. Amendment to IRC Section R309.1. X 4. The garage and its attic shall be separated from the residence and its attic area by not less than 1/2-inch gypsum board applied to the garage side. Amendment to IRC Section R309.1 and R309. X 5. Identify flame and smoke index for thermal insulations. R316, R906 X 6. Provide attic ventilation calculations for all concealed attic spaces; include required and provided net free ventilation area. Indicate the size, type, wire mesh and location of attic ventilation. Provide the following note, if applicable: "Where eave or cornice vents are installed insulation shall not block the free flow of air. A minimum of 1 inch space shall be provided between the insulation and roof sheathing at the location of the vent”. IRC Section R806. ARCHITECTURAL BUILDING CROSS SECTION COMMENTS: X 1. Cross-sections shall be cross-referenced to the floor plan and structural plans and shall accurately depict the construction at the cross-section location. R106.1.1 X 2. Identify, depict and specify requirements for draft-stopping in the attic. R502.12 ARCHITECTURAL ROOF PLAN COMMENTS: X 1. Note and specify a complete roofing assembly system including roof classification, type and grade of materials, valley and other flashing materials, underlayment, and installation requirements. R902, R903, R904, R905, R906 ARCHITECTURAL CHIMNEY & FIREPLACE REQUIREMENTS: X 1. Factory built fireplaces and chimneys (zero-clearance) shall be listed by an approved listing agency. Specify make and model number and provide the approval number of the testing agency. The manufacturer’s installation instructions shall be posted at the job site. R1002.1, R1004.1 X 2. For masonry and zero-clearance fireplaces, indicate fireplace location, hearth size and materials. R106.1.1 X 3. Note and dimension that the fireplace chimney must terminate a minimum of two feet above any point of a roof within ten feet measured horizontally and not less than 3-feet above the highest point where the chimney passes through the roof. IRC Section R1001.6, G2427.5.3 MODEL ENERGY CODE COMMENTS . X 1. Identify on the mechanical drawing the required insulation R-value for all HVAC ducts. IRC Section N1103.3 X 2. Identify on the mechanical drawing the required insulation for mechanical systems piping. IRC Section N1103.5 X 3. Identify on the window and door details/schedules the proposed U-values and solar heat gain coefficients. IRC Section N1102.1, N1102.1.3 X 4. All building joints, seams, penetrations and other sources of air leakage through the building thermal envelope shall be noted to be caulked, weather-stripped, wrapped or otherwise sealed to limit uncontrolled air movement. N1102.1.10 X 5. Recessed lighting fixtures type and rated installation requirements shall be noted on the drawing. Coordinate this with fire-resistive requirements. N1102.1.11 STRUCTURAL FOUNDATION PLAN COMMENTS: X 1. Structural concrete shall be noted to be consolidated and moist cured in accordance with ACI-318. R402.2 X 2. Fills supporting slabs on grade are limited in height. Establish the (USGS datum) existing grade contour elevations within and surrounding the proposed building along with the finish floor elevation for the new and existing buildings. R106.1.1, R506 STRUCTURAL FRAMING PLAN COMMENTS: X 1 Note on the plan that all wood materials shall bear an approved grading stamp. R502.1, R602.1, R802.1 X 2 Specify all structural material types, species, grades, etc. Wood stud and steel stud construction shall be shown to comply with the prescriptive requirements of applicable IRC Sections or the components shall be designed by an Arizona Registrant. Wood, steel, masonry and concrete components shall comply with prescriptive/empirical design requirements of IRC Sections or shall be designed by an Arizona Registrant. The proposed irregular masonry wall and wood truss building shall be appropriately designed and sealed by a qualified engineer. R301.1.3, R401, R501, R502.2, R505, R601, R602.10.10, R603, R604, R801, R1001, R1003 X 3 Girders/beams must be within the load and span limitations of IRC Table R502.5.(1) and (2) or the design shall be selected by a qualified engineer. . X 4 Specify on the drawings the design wind and seismic criteria and required floor live load, roof live load, attic live load and dead loads used for selection of joists, beams, trusses and girders. IRC Section R301. X 5 City of Tucson Amendment to Table R301.5 requires 40 psf for floor live load and 40 psf for storage or habitable attic floor. The bottom chord of attic trusses shall be designed for not less than 10 p.s.f. non-current live load or as may be required. Identify on the drawings whether or not the attic space is to be used for storage. X 6. Identify and specify structural sheathing for walls, floors and roofs. R503, R604, R803 X 7. Identify and specify on the plans required nailing per Table R602.3(1) except as may be otherwise required by sealed engineer’s design. R502.9, R602.3, R802.2 X 8. Provide complete truss calculations and truss layout plan. Truss designs submitted must include all types and be designed for the loading conditions, span, slope, and spacing designated on the framing plan. R502.11, R802.10 X 9. TRUSS SYSTEMS: Wood trusses engineered sealed designs can be submitted as a “Deferred Submittal” for custom homes only. All model homes must have truss engineered sealed designs submitted with the plans for approval. PROVIDE written authorization from David Mann for the deferred design submittal. R106.3.3 X 10. Truss calculations must be signed, dated and sealed by an Engineer in responsible charge for the truss design as a bona fide registrant in the State of Arizona. R106, R301.1.3 X 11 Roof trusses shall be attached to wall plates with approved connectors that have a resistance to uplift of not less than 175 pounds. The fastener connection to the truss shall be in accordance with the truss manufacturer’s specifications. IRC Reference R802.10.5 X 12. All truss calculations shall be appropriated cross-referenced to the truss layout and building permit roof and or floor framing plans. R106 X 13. When an architect or engineer of record is utilized for the building design that registrant must review truss document and other engineered design submittals provided by another registrant. Truss calculations shall bear an appropriate review stamp showing this review has been done. IRC Reference Sections R106.3.3, R301.1.3, R502.1.4, R502.8.2, R502.10, R502.11.3, R802.7.2, IBC Section 106.3.4 MECHANICAL PLAN COMMENTS: X 1 Provide a notation on the mechanical drawing that: All ducts shall be sealed substantiately airtight by means of approved and listed tapes (UL 181A, UL-181B) , mastics, gaskets or other approved closure systems. IRC Section M1601.3.1 X 2. Show trap, routing, pipe size and disposal point for condensate piping, emergency pan and secondary condensate line as required. Section M1411.3 PLUMBING PLAN COMMENTS X 1 Provide table of fixture unit counts for water supply piping. P2903.6, P2903.7; UPC 610 X 2. Designate the locations of water heaters. Indicate the location of the T and P relief line from the water heater to the exterior of the building. Note the T and P relief line to be full size steel pipe or hard drawn copper tubing extending to the exterior of the building and terminating in a downward position not more than 2 feet or less than 6 inches above grade. The T and P relief line shall not terminate over walkways, patios, carports or other similar areas. Show requirements for emergency drain pan and piping. P2803, P2801; UPC 505.3, UPC 510.7 X 3. Correct UPC code edition to agree with the 2003 UPC edition and State amendments as adopted by the City. UPC 103.2.3 ELECTRICAL PLAN COMMENTS: X 1. Receptacles shall be installed so that no point along the floor line in any wall space is more than 6 feet, measured horizontally, from an outlet in that space, including any wall space 2 feet or more in width. IRC Section E3801.2.1. X 2. Provide a receptacle outlet in hallways 10 feet or more in length. IRC Section E3801.10. X 3. Luminaires shall be installed so that combustible materials will not be subjected to temperatures in excess of 90-degrees centigrade (194-F). E3903.2 X 4. Thermal insulation shall not be installed above a recessed luminaire or within 3-inches of the recessed luminaire's enclosure, wiring compartment or ballast except where such luminaire is identified (Type IC ) for contact with insulation. E3904.9 X 5. Electric power to the new building is shown connected to the existing service panel. However, electrical calculations are shown only for the new building. Provide complete electrical calculations that evidence the total connected lighting and power requirements for both existing and new electrical uses. IRC Section E3502.2 OUTDOOR LIGHTING CODE: X 1. Provide catalog cuts of all new outdoor lighting fixtures identifying fixture shielding or non shielding installation conditions and output lumens for each outdoor lighting fixture. X 2. Provide on the drawing appropriate tabular calculations that identify Outdoor Lighting Code site designation, total site area, allowable lumens per Table 5.1, conditions for installation of outdoor lighting fixture type, total lumens allowed at the site, maximum unshielded lumens at the site, and the actual installed lumens at the site for each fixture type. Total lumen calculations shall include existing and new fixtures. Sincerely, BROWN & ASSOCIATES Michael J. Brown, C.B.O. President MB:ns |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/21/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 02/21/2006 | SUE REEVES | REJECT SHELF | Completed |