01/23/2006 JIM EGAN FIRE REVIEW Approved
01/30/2006 ANDREW CONNOR NPPO REVIEW Denied Submit NPPO plan or Application for Exception per DS 2-15.2.0.C
01/30/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Submit a landscape plan per DS 2-07.0 to verify that expansion area meets current code requirements, include the following information:

2. Street landscape borders are required, a street landscape border, per LUC 3.7.2.4 is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. Dimension landscape borders accordingly on landscape plan.

3. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4.

4. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border(s) per LUC 3.7.2.4.

5. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g

6. The planting plan and layout calculations will include the following Information:

· Both the proper and common name of each type of plant material must be listed.
· Locations, size, and name of all existing vegetation to remain in place.
· Note on landscape plan: All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7.

7. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I

8. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

9. Submit NPPO plan or Application for Exception per DS 2-15.2.0.C

10. Additional comments may apply.
02/07/2006 PATRICIA GEHLEN ZONING REVIEW Denied DSD TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: David Rivera
Senior Planner

PROJECT: T06CM00221
7157 East Broadway Boulevard
Addition of Storage Area and Outside Dining Area for Restaurant

TRANSMITTAL DATE: February 26, 2006

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

Just for clarification this is not a T.I. This is an expansion of building area as well as outside dining area. Please keep in mind the at the outside area must be included for parking requirements.

1. Both of the copies of drawings submitted with the drawing with the proposed changes are insufficient for determination of additional impact to the existing shopping center. It is requested that a comprehensive as built drawing depicting the entire shopping which should include the information on each use, square footage of each suite, and the overall parking requirements if the development does not qualify as a shopping center.

2. A recent lot split has occurred on the site and it is not clear whether the lot split review and approval was processed through the Development Services Department. Please provide documentation supporting the approval of the lot split. Also the plan does not include the delineation of the of the new lot lines. Please draw the new property lines and label with distance and bearings. Because the lot has been split the existing and proposed structures must be with the lot boundary. Per the drawing it appears that the outside patio may be outside the new lot boundary, please confirm compliance.

3. As a result of the expansion of the storage area along the north side of the building several and approximately nine parking space will be lost. It is acknowledged that new parking spaces are proposed but it is still not clear due to a lack of clear information if the required number of parking spaces have been provided. This will be verified once the as built drawing is submitted and reviewed.

The parking area as proposed along the West Side of the building does not appear to be within the new lot boundary. Please confirm if a cross access/cross parking agreement has been recorded or is existing and covers this issue.

The new parking area along the West Side of the building does not meet development design standards. The one way PAAL as designed does not meet the required width due to requirements for a five-foot wide pedestrian refuge area with a four-foot sidewalk between the building and the PAAL. The sidewalk area must be physically separated from the vehicular use area.

4. The loading zone should be relocated away from the parking space as depicted on the plan. The location of the loading zone if located at least 18 feet from the new parking space will provide for better and safer maneuvering into and out of the loading area.

5. The one way sign next to the door along the north side of the building should be relocated so as not create a safety concern when using the doorway.

The one way signs proposed on city right-of-way must be relocated on site or permission from the Transportation and Traffic Departments must be granted. Relocate as requested.

6. The existing and future full and half right-of-way information for Broadway Boulevard must be added to the plan (includes, drawing, labeling, and dimensioning the existing and future property lines, sidewalks and curbs. The information is required due to the close proximity of the proposed outside ding area to the property line. The future right-of-way line may affect the design of the building. Please add the requested information.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\DSD\T06CM00221.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
02/22/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: February 22, 2006
ACTIVITY NUMBER: T06CM00221
PROJECT NAME: Rockin' Baha Lobster
PROJECT ADDRESS: 7157 E. Broadway Blvd.
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. It is acknowledged that this project is a proposed addition and it is a less than 25% expansion. However the site plan must have the
2. Add lot dimensions and bearings to the site plan, sheet C-1. DS 2-02.2.1.A.5.

3. Indicate the width of the existing sidewalk (keynote 5) and the sidewalk located within the ROW. DS 2-02.2.1.A.12.

4. Indicate on the site plan the finish floor elevation of the structure. DS 2-02.2.1.A.16.

5. Add finish grades to the plan (sheet C-1) to determine the direction of drainage surrounding the structure. DS 2-02.2.1.A.16.

6. Revise the maneuvering area for the loading space so the proposed wheel stop/parking space is not impacted by the vehicle maneuvering into the loading space. DS 2-02.2.1.A.14.

7. Handicap curb access ramps are required to be constructed with truncated domes, per recent a Federal ADA requirement. Show a detail or add a general note to the site plan indicating all public and private handicap curb access ramps will have truncated domes.

8. Dimension the existing right-of-way, including the future right-of-way. Broadway Blvd is an arterial road based on the Major Streets and Routes (MS&R) Plan and has a future ½ ROW width of 75'. Show the existing curb, future curb and sidewalk location. Revise accordingly. DS 2-02.2.1.A.19.

9. Provide existing and future sight visibility triangles for both the ingress/egress east of the structure and for the one-way exit. DS 2-02.2.1.A.10.

10. Show existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. DS 2-02.2.1.A.23.

11. Indicate the location of keynote 13 on the plan view.

12. Keynote 14 depicts a do not enter sign within the ROW. Be aware this sign must be permitted through the Department of Transportation.
02/26/2006 DAVID RIVERA ZONING HC SITE REVIEW Denied see zoning comments