Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T06CM00216
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/06/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | needs wastewater 8th floor credit evaluation |
| 11/07/2007 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 11/26/2007 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T06CM00216 2728 East 5th Street Remodel & Expansion of SFR TRANSMITTAL: November 26, 2007 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1) This review is for a remodel and expansion of a single-family residence (SFR) in the R-1 zone. 2) The maximum number of bedrooms for a SFR in the R-1 zone is four (4) without additional parking in the side and rear yard. Such additional parking must meet the requirements of Development Standards 3-05 (LUC Sections 3.5.7.1.G &.H). It appears that the den meets the criterion of a bedroom per the Land Use Code (LUC). Please dimension and clarify the opening between the den and the living room on the floor plan. 3) Please fully dimension the plot plan. Provide dimensions for both the front and rear from the closest points of the structure to the property lines. Also revise the side yard setbacks to reflect the DDO requirements and so that the dimensions add up to the property dimension of fifty feet (50'-0"). Please be aware that any further revision to the plans may result in additional comments. These comments can be address over the counter. |
| 12/04/2007 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Activity: T06CM00216 Date: 12/04/07 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. I. GENERAL REQUIREMENTS: " Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. " Provide accurate drawing index numbering. II. FLOOR PLANS: " Provide a means of egress from the master bedroom that opens directly to the outdoors and meets the opening requirements of 310.1. " Specify the minimum size opening required for under-floor access (24"x18"), R408.4. III. ELEVATIONS: " Provide keynotes on the elevation page for all cross references. " Show the parapet on the East elevation. IV. SECTIONS - DETAILS: " Provide accurate cross-reference for exterior wall next to master bathroom shower. " Provide draft-stopping at concealed spaces, R602.8. " Specify attic ventilation in each rafter bay. " Eave vents require min. 1" clearance between ceiling insulation and roof sheathing, R806.3. " Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. V. PLUMBING PLAN: " Provide a water fixture unit schedule for the entire property (including existing) P2903.6. " Provide the maximum developed length of water line from the meter the furthest appliance served, and the diameter of the water line, P2903.7. " Provide keynotes on the plumbing page for the cross references. VI. MECHANICAL PLAN: " Provide mechanical ventilation for the existing bathroom, R303.3, M1507. " Provide location of return air ducts and register sizes, M1602. Minimum duct/register size: heat pump or air conditioner - 6 sq. in. / 1000 BTU, M1403.1 (1 ton cooling = 12,000 BTU). VII. ELECTRICAL PLAN: " Provide a legible electric plan. Line weight on electrical plan is too light. " Show the location of the sub-panel with a 30"W x 36"D clear working space, E3305.2, E3501.6.2. Panel boards may not be located in clothes closets or bathrooms, E3305.4. " All bedroom outlets shall be arc-fault protected (receptacles, lights, and smoke detectors), E3802.12. " Show locations of smoke detectors in the existing portion of the house. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke detectors, R313. VIII. OUTDOOR LIGHTING CODE " Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. " Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). If you have any questions please contact: Clayton Trevillyan (520) 837-4913 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/24/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 12/24/2007 | SUE REEVES | REJECT SHELF | Completed |