Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T06CM00211
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/12/2006 | AKLAPPE1 | ZONING | REVIEW | Needs Review | |
| 05/12/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Needs Review | Based on the Drainage report (Page 2) the Recommended Minimum FFE (2375.53) is 2.53 feet above existing grade. Per the Development Standards (Excavation and Grading) section 11-01.8.0 placement of fill in excess of 2 feet is not permitted. The adjacent existing home is at an elevation of 2374.95 which is 1.95 feet above existing grades. Please verify that the existing grade is 2.53 feet below the proposed FFE of the duplex. Due to the fact that fill is required a grading permit will be required if the fill quantity exceeds 50CY. Please verify the earthwork and place the quantity on the plans. If you have any questions, I can be reached at 791-5550 x1191 or Jose.Ortiz@tucsonaz.gov Jose E. Ortiz, PE Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax |
| 05/12/2006 | ANDREW CONNOR | NPPO | REVIEW | Needs Review | 1. Submit NPPO plan or Application for Exception per DS 2-15.2.0.C |
| 05/12/2006 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Needs Review | PLAN CHECK COMMENTS - PROJECT #T05CM00211 4/11/06 1315 E. HEDRICK DR. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 3. LIST THE SQUARE FOOTAGES FOR ALL THE FOLLOWING AREAS SEPARATELY ON THE DRAWINGS: - LIVABLE AREA - GARAGE - PORCH/PATIO COVERS - DECKS FOUNDATION PLANS: 1. THE ELEVATION DETAIL ILLUSTRATES INTERIOR FOOTINGS. PLEASE PROVIDE A PLAN LOCATING THESE FOOTINGS. 2. PLEASE DESCRIBE THE VERTICALS SHOWN IN THE ALTERNATE FOUNDATION DETAIL. 3. PLEASE SIZE THE UFER. IS THE LOCATION OKAY? IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |