Permit Number: T06CM00162
Parcel: 140060600

Address:
3714 E HELENA SV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T06CM00162
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2006 GERRY KOZIOL WWM REVIEW Denied needs wastewater 8th floor credit evaluation
02/15/2006 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Denied February 13, 2006 CITY OF TUCSON - FIRST CHECK
Tucson Appl. No. T06CM00162
LP2A Job No. 2060161.010

City of Tucson
201 N. Stone Ave. 1st Floor
Tucson, AZ 85701

Re: Plan Review: Moritmore Additon/Remodel
Address: 3714 E. Helena Strav

Linhart Petersen Powers Associates (LP2A), a Bureau Veritas Company, has completed a review of the following documents on behalf of the City of Tucson:

1. Plans: Two (2) sets of plans (10 sheets, SP-1 through E-1) with no dates or stamps.

2. Truss Calculations: None provided.

Structural Calculations: None provided

Energy Compliance: Two (2) sets of REScheck Compliance Certificate for Pima County, with no dates or stamps.


These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC).

Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded.


Sincerely,

LINHART PETERSEN POWERS ASSOCIATES
A Bureau Veritas Company




Randy McCoy, Senior Plans Examiner
ICC Plans Examiner









RM:pc c:/tucson\2060161.010pc1
enclosures



Re: Stories: One
Fire Sprinklers: No
Building Area (sq. ft.): 1065 (livable)
187 (garage)

A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code.

B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance.

C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.).


ARCHITECTURAL COMMENTS:

Glass in hazardous areas shall be safety glass (master bath). Specify on applicable floor plans and elevations. R308.4.

Note and dimension that the fireplace chimney shall extend at least 2 feet higher than any portion of the roof within 10 ft. Sheet A2. R1001.6.

For thin coat stucco systems over foamboard, note and specify the ICBO Evaluation Report number, system name and manufacturer. Note and specify the vapor barrier used. Sheet A2. R106.

Cross sections shall be cross-referenced to the floor plan and structural plans. Improper sheet reference. R106.

Provide attic ventilation calculations for all concealed attic spaces; include required and provided net free ventilation area. Also, indicate the type and location of attic ventilation. Provide the following note “A minimum of 1 inch space shall be provided between the insulation and roof sheathing at the location of the vent. Sheet S2. R 806.

Note and specify surface drainage. Sheet S1. R401.3.

Add brace wall panel (48”) at front side corner of Great Room. Sheet A1 & S1. R602.10.

Specify design criteria for roof line and dead loads. Sheet S2. R301

MECHANICAL, ELECTRICAL AND PLUMBING COMMENTS:

Specify materials for waste, water and gas pipes. Sheet P1. R106.

If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/17/2006 CINDY AGUILAR OUT TO CUSTOMER Completed
02/17/2006 SUE REEVES REJECT SHELF Completed