Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T06CM00162
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/03/2006 | GERRY KOZIOL | WWM | REVIEW | Denied | needs wastewater 8th floor credit evaluation |
02/15/2006 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | February 13, 2006 CITY OF TUCSON - FIRST CHECK Tucson Appl. No. T06CM00162 LP2A Job No. 2060161.010 City of Tucson 201 N. Stone Ave. 1st Floor Tucson, AZ 85701 Re: Plan Review: Moritmore Additon/Remodel Address: 3714 E. Helena Strav Linhart Petersen Powers Associates (LP2A), a Bureau Veritas Company, has completed a review of the following documents on behalf of the City of Tucson: 1. Plans: Two (2) sets of plans (10 sheets, SP-1 through E-1) with no dates or stamps. 2. Truss Calculations: None provided. Structural Calculations: None provided Energy Compliance: Two (2) sets of REScheck Compliance Certificate for Pima County, with no dates or stamps. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, LINHART PETERSEN POWERS ASSOCIATES A Bureau Veritas Company Randy McCoy, Senior Plans Examiner ICC Plans Examiner RM:pc c:/tucson\2060161.010pc1 enclosures Re: Stories: One Fire Sprinklers: No Building Area (sq. ft.): 1065 (livable) 187 (garage) A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). ARCHITECTURAL COMMENTS: Glass in hazardous areas shall be safety glass (master bath). Specify on applicable floor plans and elevations. R308.4. Note and dimension that the fireplace chimney shall extend at least 2 feet higher than any portion of the roof within 10 ft. Sheet A2. R1001.6. For thin coat stucco systems over foamboard, note and specify the ICBO Evaluation Report number, system name and manufacturer. Note and specify the vapor barrier used. Sheet A2. R106. Cross sections shall be cross-referenced to the floor plan and structural plans. Improper sheet reference. R106. Provide attic ventilation calculations for all concealed attic spaces; include required and provided net free ventilation area. Also, indicate the type and location of attic ventilation. Provide the following note “A minimum of 1 inch space shall be provided between the insulation and roof sheathing at the location of the vent. Sheet S2. R 806. Note and specify surface drainage. Sheet S1. R401.3. Add brace wall panel (48”) at front side corner of Great Room. Sheet A1 & S1. R602.10. Specify design criteria for roof line and dead loads. Sheet S2. R301 MECHANICAL, ELECTRICAL AND PLUMBING COMMENTS: Specify materials for waste, water and gas pipes. Sheet P1. R106. If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/17/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
02/17/2006 | SUE REEVES | REJECT SHELF | Completed |