Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T06CM00014
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/11/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T06CM00014 .. 1435 SOUTH 6TH AVENUE .. SITE FOR NEW MODULAR AUTO SALES OFFICE .. DGL .. 1ST REVIEW .. 1/13/06 .. S1. Provide copy of State of Arizona Permit for new modular office, prior to approval of this Permit. S2. Clarify detail 5/A0.0, by adding property line and locating fence to be entirely inside property line and state total length of picket fence required for the project, 1997 U.A.C. Sec 302. S3. Provide adequate number of grade elevations to show accessibility for the accessible route from the public way to the finish floor elevation of the building, including access aisle at parking, ramps. landings, stairs, and parking space. S4. Provide construction design and details, including structural design and calculations for the ramp, stair, landings and railings, at the handicapped ramp, ref 2003 IBC Sec 11 and ANSI A117.1- 2003ed Sec 3 and 4. S5. Provide maneuvering clearances at accessible route/s (sidewalks) per IBC and ANSI sec 4, at turns and stair landing for access to the ramp landing. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
| 01/18/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or Application for Exception per DS 2-15.2.0.C |
| 01/26/2006 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 01/30/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | January 30, 2006 Site Plan Review for T06CM00014 Reviewer: Loren Makus, E.I.T. The site plan cannot be approve at this time. The following comments must be addressed. 1. Show how that water harvesting will be maximized in the new landscaped area. The landscape area should be depressed up to 6 inches and should be designed to accept runoff from adjacent areas. (LUC Section 3.7.4, Use of Water, Section 3.7.4.3.B, Storm Water Runoff) 2. Clarify on the Site Plan that the east portion of the lot will remain undeveloped. Revise the note that indicates that the entire lot is to be paved with asphalt paving. Clearly indicate the extent of pavement and clearly delineate the areas that will not be paved. 3. Provide a north arrow and scale. The plan should be drawn in a standard engineering scale. (DS 2-02.2.1.A) 4. Show drainage patterns for the site and indicate that roof drainage or other concentrated will not be directed over any pedestrian route. (DS 2-08.3.1) 5. Provide estimated cut and fill quantities. DS 2-02.2.1.A.17) The building plans cannot be approved until the site plan has been approved. If you have any questions you may contact me at loren.makus@tucsonaz.gov or at 520.791.5550 ext. 1161. |
| 02/22/2006 | TERRY STEVENS | ZONING | REVIEW | Denied | 02/24/06 Development Services Department Zoning Review Section Terry Stevens Lead Planner T06CM00014 Comments: 1. The building plans have been reviewed but cannot be approved at this time. An approved and stamped site plan is required prior to approval of the building plans. 2. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/28/2006 | AOLIVO1 | OUT TO CUSTOMER | Completed |
| 02/28/2006 | SUE REEVES | REJECT SHELF | Completed |