Permit Number: T06BU02851
Parcel: 105120120

Address:
4275 N STONE AV

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T06BU02851
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/16/2008 LOREN MAKUS ENGINEERING REVIEW Denied January 23, 2008
T06BU002851
Loren Makus, EIT
The proposed right-of-way improvements shown along Stone Avenue don't match up with the existing improvements. Revise the plan to show the proposed improvements matching the existing.
The grades in the southern perimeter yards are not consistent with the drainage arrows and the referenced detail. Revise the plan to be consistent.
Provide specifications for the drain-through openings in the perimeter walls. Indicate the size and frequency of the openings.
If there are walls proposed between the individual lots, indicate the size of the required drainage openings. If patio walls are not to be built, indicate so on the grading plan.
Make sure the pointers on the keynote callouts point to the described feature.
Clearly show the general dimensions of the basin.
Show in the detail or in the plan view how vehicle access to the basin will be controlled.
Revise the plan to eliminate overlapping data.
The graing limits on the east property boundary are not consistent with the referenced detail. Revise as necessary.
Provide sufficient detail for construction of the basin, including top bank elevations and slopes. Indicate that the basin will be graded to drain.

Provide a complete, revised SWPPP as indicated in the previous comments.

Include a copy of the approved tentative plat and drainage report. Additional comments may be forthcoming.
12/20/2007 MICHAEL ST. PAUL ZONING REVIEW Denied December 20, 2007

Development Services Department
Zoning Review Section

Michael St.Paul
Planning Technician

T06BU02851 Grading Plans for S05-061

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved final plat for the condominiums. Please submit one copy of the CDRC approved and stamped final plat, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved and stamped tentative plat. Additional comments may be forthcoming.
12/24/2007 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved final plat including landscape and native plant plans for reference. The grading application will be reviewed for compliance only when the approved documents are included in the submittal. Revise grading plans as necessary to comply with the approved plans.