Permit Number: T06BU02786
Parcel: 12205030C

Address:
4416 E EDISON ST

Review Status: Completed

Review Details: GRADING

Permit Number - T06BU02786
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/14/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: December 14, 2006
ACTIVITY NUMBER: T06BU02786 / T06OT03088
PROJECT ADDRESS: 4416 East Edison Street
PROJECT REVIEWER: Patricia Gilbert

The following items must be revised or added to the grading plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: GRADING PLAN

1. Please label the plan Site plan / Grading Plan in all applicable areas.

2. Provide the original approved plot plan for the existing structure.

3. Provide a general note stating, "This property is within the FEMA Flood Hazard Zone X Shaded and is subject to the City of Tucson Floodplain Requirements." Include the FIRM Panel number in the general note, " FIRM Panel 04019 C 2232." DS 2-02.2.1.A.15.

4. Provide a general note on the site plan that this development contains a requirement that the applicant, or the applicant's authorized representative, complete a FEMA Elevation Certificate and is returned to the Development Services Department (DSD) Engineering Division prior to approval of final inspection. The original elevation certificate must be returned to the DSD Engineering Division.

5. The water surface elevations (WSE) for the existing structure to the east and for the building pad must be provided. Adjacent to each WSE provide the required FFE for each structure. Indicate the datum used, if the datum is different then the datum used in the submitted hydrology report also provide the JE Fuller's recommended WSE and FFE with the datum.

6. Provide copies of the completed elevation certificates for the pad and the structure.

7. Provide contours, spot elevations and Bench Mark based on a City of Tucson datum. DS 2-02.2.1.A.23.

8. Provide finish grades at the boundaries of the fill pad.

9. Provide the activity numbers on the plan.
12/18/2006 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved site plan including native plant preservation plans or application for exception. The grading application will be reviewed for compliance only when the approved documents are included in the submittal.
12/29/2006 DAVID RIVERA ZONING REVIEW Denied 12/29/06

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved and stamped site plan or CDRC approved and stamped Record of Survey drawing.
Please submit two copies of the applicable approved and stamped site plan or CDRC approved and stamped Record of Survey, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan or CDRC approved and stamped Record of Survey drawing. Additional comments may be forthcoming.

4. Please ensure that the grading plan matches the approved and stamped site plan or CDRC approved and stamped Record of Survey drawing.

5. It is further acknowledged that the the property is within a floodplain and subject to compliance with floodplain regulations.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/05/2007 CINDY AGUILAR OUT TO CUSTOMER Completed
01/05/2007 SUE REEVES REJECT SHELF Completed