Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T06BU02763
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/17/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Richard A. Sarti DATE: January 23, 2007 Rick Engineering Co. 1745 E. River Road, Ste. 101 Tucson, Arizona 85718 SUBJECT: Alamo Lofts, 6105 E. Pima Street Grading Plan T06BU02763 (First Review) T14S, R14E, Section 01 RESUBMITTAL REQUIRED: Grading Plan, Drainage Report and SWPPP The Grading Plan (GP), Drainage Report (DR) and Stormwater Pollution Prevention Plan cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies of the GP. 2. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 3. Add note to Grading Notes: "All grading shall conform to the City of Tucson Development Standard 11-01.0, Excavation and Grading. 4. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting" 5. List Grading Plan number (T06BU02763) on each sheet of the grading plans. 6. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 7. Cut or fill slopes require a 2' minimum setback from property line. 8. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address. 9. Call out peak discharges entering and exiting the site. Drainage report: 1. The DR has been accepted by Engineering. 2. Re-submit the DR along with the corrected copies of the Grading Plan. Stormwater pollution prevention plan: 1. The SWPPP has been conditionally approved provided that the list of items in your response letter will be taken care of within a reasonable amount of time. 2. Re-submit the SWPPP along with the corrected copies of the Grading Plan. Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/6105 E. Pima St. Grad |
| 12/19/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved tentative plat including landscape and native plant preservation plans for reference. The grading application will be reviewed for compliance only when the approved documents are included in the submittal. Revise grading plans as necessary to comply with the approved tentative plat. |
| 12/29/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | 12/29/06 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved tentative plat/development plan. Please submit one copy of the CDRC approved and stamped tentative plat/development plan, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved and stamped tentative plat/development plan. Additional comments may be forthcoming. 4. A site card with DSD approvals by Fire, Zoning, Handi-cap, Engineering, and Landscape/NPPO including the approved tentative plat/development plan stamped for site plan approval and signatures is required before the grading plan can be approved by Zoning. Two copies of the CDRC approved tentative plat/development plan, landscape and NPPO plans are to be submitted with the grading plan packet for processing and approval as a site plan. No fees are involved in re-stamping the tentative plat/development plan plans as an approved site plan. The tentative plat/development plan may be walked through for stamps and site card sign off. Submit the following: two copies of the stamped development plan, landscape and NPPO plans must be included with the grading plans packet processed together for site approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/31/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 01/31/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/31/2007 | GERARDO BONILLA | REJECT SHELF | Completed |