Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Permit Number - T06BU02071
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
| 09/18/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T06BU02071 .. 6974 SOUTH EGRET DRIVE .. DGL .. 1ST REVIEW COMMENTS .. .. #S1 THROUGH #S14 .. 9/18/06 .. S1. Provide completed Commercial Plan Submittal Checklist by Architect of Record, including: Signature of Architect/Engineer of Record, Registration number of Registrant of Record, Date form is completed, Job Address and Acknowledge items listed on this Checklist are in this Submittal by checking the adjacent square. See DSD website : www.tucsonaz.gov/dsd, for form. S2. Provide completed Code Review Checklist, as required by 1997 Uniform Administrative Code Section 302.1, including: Job Address, Architect, Signature, Date, Summary of Governing Regulations, General Building Summary and Allowable Area Calculation. See DSD website : www.tucsonaz.gov/dsd, for form. S3. Provide: Common Area 'B' Legal Description on the drawings, architectural site showing and annotating project property lines, locating new structure dimensionally from two adjacent property lines and from new/existing structure/s, identify existing and new structures on site by occupancy and type of construction. S4. This structure appears not to be an A-3 Occupancy but may be a 'B' Occupancy, so please reevaluate Occupancy classification based on function and Occupant Load, per 2003 IBC Section 3 and 303.1.1. S5. State Occupancy of shade structure on drawings S6. State TYPE OF CONSTRUCTION of the shade structure on the drawings S7. State OCCUPANT LOAD of the shade structure on the drawings S8. State CODES used on drawings. S9. Please verify other items commonly provided with canopies, ie: tables, seating, etc., are included with this Building Permit or a Building Permit will be obtained in the future for these items, by notation on drawings. S10. Address accessibility requirements, per IBC Section 11 and ANSI A117.1-2003ed, on drawings from the Public way to and including the ramada. S11. Provide adequate spot elevations to show accessibility. S12. Provide address on canopy per Pima County Addressing Ordinance and per IBC Section 501.2. S13. Provide material specifications, on the drawings, for materials used in construction of ramada. S14. Special Inspection is required per 1997 UAC Section 306 for : 1. Shop welding. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111, email at <Doug.Laakso@tucsonaz.gov.> or visit City of Tucson , DSD website : www.tucsonaz.gov/dsd. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/02/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 10/02/2006 | SUE REEVES | REJECT SHELF | Completed |