Permit Number: T06BU01910
Parcel: Unknown

Address:
2364 E DREXEL RD

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T06BU01910
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2007 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved tentative plat including landscape and native plant preservation plans for reference. The grading application will be reviewed for compliance only when the approved documents are included in the submittal. Revise grading plans as necessary to comply with the approved tentative plat.

The grading plan has been reviewed by the Landscape / NPPO Section but cannot approve the plan until all Engineering, comments, concerns, and appropriate revisions have been addressed
05/09/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond TO: Rick Engineering
SUBJECT: Tres Pueblos Norte S05-180 Grading Plan 2nd Resubmittal Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBERS: T06BU01910

Reseed bond amount: $20,691.00 based on updated disturbance area

SUMMARY: Engineering Division of Development Services Department reviewed the revised Grading Plan package and response letter. Engineering maintains conditional approval of the grading permit. The Tentative Plat shall be formally approved by CDRC, and, all grading comments are addressed prior to grading permit issuance. Assure the revised (if needed) drainage report, 4 copies of the revised grading plan, and 4 copies of the SWPPP are provided to reflect the remaining conditions of approval:

GRADING PERMIT CONDITIONS OF APPROVAL:
1) City of Tucson Development Standards (DS) Section No.2-03.5.2: The grading plan cannot be approved unless it is in conformance with an approved tentative plat. Provide a copy of the approved Tentative Plat with resubmittal.
2) DS Sec.11-01.4.1.C: The grading plan will require easement information prior to issuance of grading permit. Show all existing easements as listed in the current Title Report Schedule B on the plan with recordation information, locations, widths, and purposes. If the easement is not in use and proposed for abandonment, so indicate. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Label docket / page for the temporary construction easement / drainage maintenance easement for the proposed drainage improvements (spillway and bleeder pipe) along west property boundary.
3) DS Sec.11-01.4.1.C: For Lot Grading details, per geotechnical Letter dated September 14, 2006, identify 1 to 2 feet setback from swale to foundation for sideyard drainage section detail on sheet 3. This setback is a minimum setback in other words the detail should reflect that the edge of the swale is at least 1-2 feet from foundation; the revised detail depicts a swale adjacent to foundation. Revise detail Section 2-2 on sheet 4.

After Tentative Plat approval, please submit four copies of the revised grading plan, docket/page of offsite easement, and the other items as previously submitted. If you have any questions, I can be reached at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
05/21/2007 MICHAEL ST. PAUL ZONING REVIEW Denied May 21, 2007

Development Services Department
Zoning Review Section

Michael St.Paul
Planning Technician

T06BU01910 Grading Plans for S05-180

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Landscape Review Sections and until all zoning comments or concerns have been addressed. In addition, all matters of conditional approval from Engineering must be resolved.

2. Zoning could not verify that the grading plan was in compliance with the approved tentative plat. Please submit one copy of the CDRC approved and stamped tentative plat, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved and stamped tentative plat. Additional comments may be forthcoming.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/21/2007 GERARDO BONILLA OUT TO CUSTOMER Completed
05/21/2007 GERARDO BONILLA REJECT SHELF Completed