Review Details: GRADING
Permit Number - T06BU01785
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/02/2006 | JOE LINVILLE | NPPO | REVIEW | Denied | Submit a copy of the approved development plan, landscape plan, and native plant preservation plan. The grading plans will be reviewed for conformance with the approved plans. |
| 09/11/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: September 18, 2006 TO: Kevin Hall, DCC SUBJECT: Merit Foods, Grading Plan Review REVIEWER: Loren Makus ACTIVITY NUMBER: T06BU01785 SUMMARY: The Grading Plan was reviewed by Development Services Department Engineering Division. The Grading Plan was not approved at this time. Grading Plan comments: 1. Include a copy of the stamped approved Development Plan with the grading permit application. Additonal comments may be forthcoming once the Development Plan is compared with the grading plan. 2. This is the first grading submittal for this grading permit application. Please note that after the second review, all subsequent reviews will be charged an hourly rate. 3. The truck loading dock area on the east side of the proposed building appears to be likely to hold ponded water. Provide for removing the water that may collect in this area. 4. Revise the access ramps adjacent to the front of the building. The truncated domes should be used only where a pedestrian use area abuts a vehicle use area without a vertical separation. Truncated domes should be removed from the ramps in this one location. The domes at the edge of the sidewalk area is sufficient. 5. Clearly delineate the limits of disturbance on the grading plan. SWPPP Comments 6. Revise the SWPPP to provide a sediment control on the upstream side of the basin outlet pipe. Revise the Grading Plan to address all of these comments and resubmit four copies of the grading plan and three copies of the SWPPP. If you would like to meet with me to discuss any of these comments please call me at (520) 791-5550 ext. 1161 or email me at loren.makus@tucsonaz.gov. Loren Makus, E.I.T. Senior Engineering Associate Engineering Division Development Services |
| 09/15/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | 09/15/06 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved development plan. Please submit two copies of the approved and stamped development, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved site/development plan. Additional comments may be forthcoming. 4. A site card with DSD approvals by Fire, Zoning, Handi-cap, Engineering, and Landscape/NPPO including the approved development plan stamped for site plan approval and signatures is required before the grading plan can be approved by Zoning. Two copies of the approved development plan, landscape and NPPO plans are to be submitted with the grading plans packet for processing and approval as a site plan. No fees are involved in re-stamping the development/tentative plat plans as an approved site plan. The development plan may be walked through for stamps and site card sign off. Submit the following: two copies of the stamped development plan, landscape and NPPO plans must be included with the grading plans packet processed together for site approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/21/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 09/21/2006 | SUE REEVES | REJECT SHELF | Completed |