Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06BU01725
Parcel: 113071220

Review Status: Completed

Review Details: POOL:COMM-MODEL

Permit Number - T06BU01725
Review Name: POOL:COMM-MODEL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/15/2006 HEATHER THRALL ZONING REVIEW Approved
09/21/2006 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. No records have been found to show that the proposed alternative to a manufactured safety release system, as designed by Alan Money, has been accepted by the City of Tucson. Provide evidence, including testing by an approved testing agency, to substantiate the claim that the proposed alternative to a manufactured safety release system complies with the intent of ASME A112.19.17 to prevent high vacuum suction entrapments. Reference Section 301.2, UPC 2003.
2. The submitted design for the pool and spa installation does not indicate the source, location, or sizing of the water, natural gas, or the wastewater piping for the project. Reference Section 103.2.3, UPC 2003.
09/21/2006 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved