Review Details: POOL:COMM-MODEL
Permit Number - T06BU01725
Review Name: POOL:COMM-MODEL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/18/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The site plan submitted with this project was revised without the knowledge or permission of the registrant and is in violation of ARS 32-125 (D). It is unlawful for any nonregistrant to cause or permit the illegal use of a registrant's seal, signature or stamp on any document prepared by the nonregistrant. Provide a properly sealed site plan. 2. The font size used on the drawings shall be a minimum of 1/8-inch (all upper case). Reference Section 302.3, Uniform Administrative Code, 1997. 3. Provide evidence, including testing by an approved testing agency, to substantiate the claim that the proposed alternative to a manufactured safety release system complies with the intent of ASME A112.19.17 to prevent high vacuum suction entrapments. Reference Section 301.2, UPC 2003. 4. Provide a complete design for the circulation, filtration, water supply, wastewater disposal, and heating of the pool and spa. Reference ANSI/NSPI-1 2003 and ANSI/NSPI-2 1999. |
| 07/18/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide a complete design for heating of the pool and spa, including listing information for all equipment. Reference Section 106.3.1, IMC 2003. 2. The font size used on the drawings shall be a minimum of 1/8-inch (all upper case). Reference Section 302.3, Uniform Administrative Code, 1997. |
| 07/26/2006 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 08/11/2006 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Denied | 1) Site plan- provide a site plan that is more legible, one that all notes and dimensions can be read. 2) Specify the accessible route for ADA, dimension gate clearances, and slope of ramps. 3) Show and specify height of latch on gate, gate shall be self-closing. 4) How is the soil categorized A',B' ETC. By a soil report? CLARIFY! |
| 08/28/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | 08/28/06 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The submitted plan for the POOL and structures has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that a revised site plan has been approved and stamped. If a revised site plan has been submitted for review and approval with the proposed expansion, please submit two copies of the approved and stamped site, landscape, and NPPO plans. 3. Zoning will re-review the POOL and structures plan on the next submittal to ensure compliance with the approved and stamped revised site plan. Additional comments may be forthcoming. 4. If a revised site plan has not been submitted for review and approval, please refer to development standards 2-02 for site content and design. The site plan must be drawn to comply with the Development Standards 2-02 and standards relevant to pedestrian access, parking, and landscaping, setbacks, etc. |