Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T06BU01679
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/07/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit a copy of the approved landscape plans for reference. The grading application will be reviewed only when the approved documents are included in the submittal. |
| 12/18/2006 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T06BU01679 Grading for T06CM03296 2140 West grant Road TRANSMITTAL: December 18, 2006 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. NPPO and Engineering approval is required prior to approval from Zoning. The last stamped approved site plan has been provided with this submittal. Please see the previous comments by David Rivera for further information. |
| 12/28/2006 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: December 29, 2006 SUBJECT: Grading Plan for TRS Home Furnishing- 2nd Engineering Review TO: Stantec Consulting, Inc Attn: Tom Lenczycki LOCATION: 2140 W Grant Road, T13S R13E Sec33, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: T06BU01679 SUMMARY: Engineering Division of Development Services Department has received and reviewed the grading plan and the Stormwater Pollution Prevention Plan (SWPPP) and does not recommend approval of the grading plan or SWPPP at this time. The following items need to be addressed: GRADING PLAN COMMENTS: 1) DS Sec.11-01.4.1.C.1: Revise the location map to identify conditions within the square mile area shown such as section corners. The location map must be to scale, 1-inch is equal to 3 miles and must have a brief legal description identifying Township, Range and Section. 2) DS Sec.11-01.4.1.C.4: Provide on the grading plan all information associated with the drainage report. Grading standards may be accessed at http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf. The following information must be indicated on the grading plan: a) Provide the ponding limits in the parking lot for the existing scuppers and storm drain. Ponding limits must be shown on plan view to verify that minimum ponding depth for the parking lot has been met. b) Provide ponding limits for the proposed grate and scupper associated with the truck well located at the back of the existing Safeway store. Revise the detail for the grate and scupper to show how it is drained away from the building and into an associated storm drain. Provide spot elevations along the storm drain to assure positive drainage. 3) DS Sec.2-08.5.1.A: Revise Grading Note #8, on sheet C1.4, on the grading plan to label the required minimum 4-foot wide sidewalk to be installed to avoid any obstruction which decreases the minimum width to less than 4 feet. General Note #8 does not state sidewalk to be constructed with an unobstructed 4-foot wide path. STORMWATER POLLUTION PREVENTION PLAN: The SWPPP does not meet the minimum requirements of the AzPDES Construction General Permit (CGP). Revise the SWPPP according to the following comment: 4) CGP Part IV.J.1: Provide a signed project manager/owner certification and contractor certifications form (if available). The owner must sign a certification form that can be provided separately or superimposed onto the SWPPP Exhibit. The NOI is not the same as a certification form. GENERAL COMMENTS: Please provide a revised grading plan and a revised SWPPP. All documents including drainage reports and geotechnical reports must be provided at re-submittal with the complete package. The drainage report and geotechnical report will be kept on file with the Records Department of Development Services. The revised grading plan and revised SWPPP must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the grading plan and SWPPP. For any questions or to schedule a meeting, call me at 791-5550, extension 1189. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/03/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/03/2007 | SUE REEVES | REJECT SHELF | Completed |