Permit Number: T06BU01650
Parcel: 133231880

Review Status: Completed

Review Details: GRADING

Permit Number - T06BU01650
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/18/2006 JOE LINVILLE NPPO REVIEW Denied Submit approved site and landscape plans.
Submit a native plant preservation plan or application for exception. LUC 3.8.4.2
08/02/2006 PAUL MACHADO ENGINEERING REVIEW Denied To: Tait and Associates DATE: August 8, 2006
Architects
2266 S. Dobson Rd. Ste. 208
Mesa, Arizona 85202

SUBJECT: 7770 E. Speedway Blvd.
Site plan T04CM003790, Grading plan T06BU01650 (First Review)
T14S, R15E, Section 08

RESUBMITTAL REQUIRED: Site Plan, Grading Plan and Drainage Statement.

The Site Plan (SP), Grading Plan (GP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan, Grading Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. The SP and GP cannot be approved prior to the site plan (T06CM03381) that is currently under review. The site plan currently under review and must include all the proposed improvements associated with the Fry's gas station. It is advised that the Fry's gas station be approved prior to the site plan (T06CM03381) because the later site plan shows the entire site showing the proposed gas station as parking spaces that are subject to change.
3. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207.
4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The SVT at the NW portion of the property is a pedestrian SVT because of the median in Speedway blvd. Revise as required.
5. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
6. Sidewalks, curbs and wheelchair ramps are required where applicable per D.S. 3-01.3.0 and installed with "Detectable Warnings" per ADAAG.
7. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
8. Show Site plan (T06CM03790) and Grading plan (T06BU01650) number on all sheets per D.S. 2-02.2.1.29.
9. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
10. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
11. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
12. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
13. List the consulting engineer and the owner/developer on the plans with the pertinent information.
14. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
15. Submit 4 copies of the grading plan upon re-submittal.

Drainage Statement:
1. The DS has been conditionally accepted.
2. Indicate the use of water harvesting techniques in the DS.
3. Incorporate the drainage exhibits into the DS with pockets.
4. Show the project address or administration address on the cover sheet of the DS.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/7770 E. Speedway Blvd. Site&Grad
08/28/2006 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT:FRY'S GAS STATION ADD - 7770 E. Speedway Blvd.
T06BU01650
Grading Plan (1st Review)

TRANSMITTAL DATE: September 08, 2006

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please call Steve Shields,
(520) 791-5608 ext. 1180.

C:\planning\grading\t06bu01650.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved site plan and additional requested documents

Final Status

Task End Date Reviewer's Name Type of Review Description
09/11/2006 GERARDO BONILLA OUT TO CUSTOMER Completed
09/11/2006 SUE REEVES REJECT SHELF Completed