Permit Number: T06BU01435
Parcel: 14101111G

Review Status: Completed

Review Details: RESUBMITTAL - GRADING

Permit Number - T06BU01435
Review Name: RESUBMITTAL - GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2006 DAVID RIVERA ZONING REVIEW Denied 11/20/06

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections.

2. Zoning could not verify that the grading plan was in compliance or verify the changes/revisions based on the last approved grading plan. Please submit a copy of the previously approved plans for comparison.

3. Zoning is willing to re-review and approve the grading plan over the counter once Engineering has reviewed and approved the revised plan.
12/01/2006 ANDREW CONNOR NPPO REVIEW Denied Submit a NPPO plan per DS 2-015.0. to verify that Borrow Pit area meets minimum requirements. The NPPO summary shall include:

1. Limits of all areas to be graded.
2. Location of proposed roads and utility easements.
3. Existing topographic contours at two (2) foot maximum contour intervals.
4. Disposition of all Protected Native Plants keyed to the inventory list and showing the following designations:
a. Plants to be preserved-in-place.
b. Plants to be salvaged and transplanted on-site. To the extent possible, plants should be transplanted directly to their permanent location on-site.
c. Plants to be salvaged and removed from the site.
d. Plants to be destroyed.
5. The location of a temporary holding nursery to be used for salvaged plants.
6. A temporary watering system must be installed.

7. Add note to NPPO plan and reference on grading plan: Fencing shall be required during construction per DS 2-06.8.0 Fig.1 for all undisturbed natural desert areas of Protected Native Plants and for individual Protected Native Plants to be preserved-in-place. The area to be fenced shall be beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. For Saguaros and cacti, the area to be fenced shall be equal to the distance of one-half (½) the height of the plant per DS 2-15.6.0

8. Add note to NPPO plan: NPPO pre permit inspection is required prior to grading inspection can be scheduled by calling IVR system and entering inspection code 09015 or calling Landscape Field Representative directly @ 791-5550 EXT 1140
12/21/2006 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 12/21/2006,

Submit an approved copy of the Tentative Plat for review to continue.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/28/2006 GERARDO BONILLA OUT TO CUSTOMER Completed
12/28/2006 SUE REEVES REJECT SHELF Completed