Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING
Permit Number - T06BU00777
Review Name: RESUBMITTAL - GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/26/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree per LUC 3.7.2.3. The measurement is always within the planter area and does not include any material which defines the outer edge of the unpaved area" per DS 2-06.3.3.C. Include inside dimensions or planter detail on the grading plans. |
| 07/06/2006 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | Gerardo Calza DATE: July 11, 2006 Urban Engineering FROM: Jose E. Ortiz, PE 877 S Alvernon Way Engineering Division Tucson, Arizona 85711 SUBJECT: Fairview Business Park Grading Plan T06BU00777 (Second Review) T13S, R13E, Section 35 RESUBMITTAL REQUIRED: Grading Plan, Drainage Report and SWPPP The Grading Plan (GP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies of the GP. 2. Cross reference sheet numbers of all details to call outs on plan view. 3. Dimension and callout limits of riprap on sheet 6 4. Due to the close proximately of the underground retention basin to Lot 6 ensure that the perforation of stormwater from this system will not create an adverse condition to the proposed overlying slab foundation of Lot 6. This information and be presented in a Geo-Technical report and/or the Drainage Report. Drainage report: 1. No additional comments SWPPP: 1. On the SWPPP site map provide additional information in regards to how the new catch basins are going to be protected. Keynote 2 does not appear to apply. Insert modified site map into SWPPPs If you have any questions, I can be reached at 791-5550 x1191 or Jose.Ortiz@tucsonaz.gov Jose E. Ortiz, PE Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax |
| 08/17/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | 08/17/06 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved tentative plat. Please submit one copy of the CDRC approved and stamped tentative plat, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the CDRC approved and stamped tentative plat. Additional comments may be forthcoming. 4. There areas depicted on the grading plan that do not match the approved tentative plat. Please review all plan sheets and ensure that the design of the development with regards to building area, parking landscaping etc. as approved on the tentative plat/development plan is depicted on the grading plan. Deviations from the tentative plat/development plan will require a resubmittal and approval of the revisions through the CDRC process. 5. Review the details on sheet 3 of the grading plan and revise detail F, M, R, and Q. Some of the details have been annotated with incorrect dimensions and and others with incorrect text. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/06/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 09/06/2006 | SUE REEVES | REJECT SHELF | Completed |